I-123 MIBG imaging and heart rate variability analysis to predict the need for an implantable cardioverter defibrillator.
- Division of Cardiology and Department of Nuclear Medicine, Montefiore Medical Center, Bronx, NY.
Abstract
BACKGROUND
Iodine 123 metaiodobenzylguanidine (MIBG) imaging and heart rate variability (HRV) analysis were compared in patients with an implantable cardioverter defibrillator (ICD) who did and did not receive defibrillator discharges. Although the ICD has been shown to abort potentially fatal ventricular arrhythmias, identification of patients who most benefit from this device remains difficult. As the autonomic nervous system has been implicated in the genesis of these arrhythmias, we undertook a pilot study to evaluate local myocardial sympathetic innervation with the use of I-123 MIBG myocardial imaging, as well as central autonomic tone with the use of HRV, in patients with implantable defibrillators. Test results were correlated with the occurrence of ICD discharges.
METHODS AND RESULTS
Seventeen patients with previously implanted defibrillators were studied. Of these, 10 had at least 1 appropriate device discharge for ventricular tachyarrhythmias, whereas 7 had no discharge. Patients with a discharge had a significantly lower I-123 MIBG heart-mediastinal tracer uptake ratio, higher I-123 MIBG defect scores, more extensive sympathetic denervation, and significantly reduced values for several HRV parameters, particularly those in the frequency domain. When combined, the I-123 MIBG heart-mediastinal ratio and HRV 5-minute low-frequency variables were highly predictive of defibrillator discharges. All patients with a heart-mediastinal ratio lower than 1.54 and 5-minute low frequency lower than 443 ms(2) had an ICD discharge (4/4), whereas no patient with an uptake ratio greater than 1.54 and 5-minute low frequency greater than 443 ms(2) did (0/3, P =.03).
CONCLUSIONS
Cardiac autonomic assessment using a combination of myocardial scintigraphic and neurophysiologic techniques may help select patients who would most benefit from an implantable defibrillator by identifying those at increased risk for potentially fatal arrhythmias.
References
Circulation. 1998 Nov 24;98(21):2334-51
J Am Coll Cardiol. 1993 Nov 1;22(5):1344-53
N Engl J Med. 1996 Dec 26;335(26):1933-40
J Am Coll Cardiol. 1999 Oct;34(4):959-65
Cited by 176 citations (total)
Journal Article Review
Cardiac metaiodobenzylguanidine imaging and heart failure.
Electronic publication date June 24, 2014
Tomoaki Nakata [...] Hirohito Sugawara et al.
The autonomic nervous system has pivotal roles in pathophysiology and prognosis in patients with heart failure. Cardiac (123)I-labeled metaiodobenzylguanidine (MIBG)...
Comparative Study Evaluation Study Journal Article Multicenter Study
Assessment of I-mIBG and Tc-tetrofosmin single-photon emission computed tomographic images for the prediction of arrhythmic events in patients with ischemic heart failure: Intermediate severity innervation defects are associated with higher arrhythmic risk.
Electronic publication date February 27, 2018
Mark I Travin [...] Hein J Verberne et al.
RATIONALE
I-mIBG planar image heart-to-mediastinum ratios effectively risk-stratify heart failure (HF) patients. The value of single-photon emission computed tomographic (SPECT) imaging...
Conflict of interest statement
MeSH
- •
- •
Specialties
Substances
- •