Publications

Clinical Trial
Controlled Clinical Trial Journal Article Research Support, Non-U.S. Gov't
Ppublish 176 citations
Electronic publication date
July 23, 2003

View on Pubmed.gov 12673176 | View on doi.org 10.1067/mnc.200...

I-123 MIBG imaging and heart rate variability analysis to predict the need for an implantable cardioverter defibrillator.

Search for publications in this journal J Nucl Cardiol - 10(2):121-31

Abstract

BACKGROUND

Iodine 123 metaiodobenzylguanidine (MIBG) imaging and heart rate variability (HRV) analysis were compared in patients with an implantable cardioverter defibrillator (ICD) who did and did not receive defibrillator discharges. Although the ICD has been shown to abort potentially fatal ventricular arrhythmias, identification of patients who most benefit from this device remains difficult. As the autonomic nervous system has been implicated in the genesis of these arrhythmias, we undertook a pilot study to evaluate local myocardial sympathetic innervation with the use of I-123 MIBG myocardial imaging, as well as central autonomic tone with the use of HRV, in patients with implantable defibrillators. Test results were correlated with the occurrence of ICD discharges.

METHODS AND RESULTS

Seventeen patients with previously implanted defibrillators were studied. Of these, 10 had at least 1 appropriate device discharge for ventricular tachyarrhythmias, whereas 7 had no discharge. Patients with a discharge had a significantly lower I-123 MIBG heart-mediastinal tracer uptake ratio, higher I-123 MIBG defect scores, more extensive sympathetic denervation, and significantly reduced values for several HRV parameters, particularly those in the frequency domain. When combined, the I-123 MIBG heart-mediastinal ratio and HRV 5-minute low-frequency variables were highly predictive of defibrillator discharges. All patients with a heart-mediastinal ratio lower than 1.54 and 5-minute low frequency lower than 443 ms(2) had an ICD discharge (4/4), whereas no patient with an uptake ratio greater than 1.54 and 5-minute low frequency greater than 443 ms(2) did (0/3, P =.03).

CONCLUSIONS

Cardiac autonomic assessment using a combination of myocardial scintigraphic and neurophysiologic techniques may help select patients who would most benefit from an implantable defibrillator by identifying those at increased risk for potentially fatal arrhythmias.

References

Circulation. 1998 Nov 24;98(21):2334-51

J Am Coll Cardiol. 1993 Nov 1;22(5):1344-53

N Engl J Med. 1996 Dec 26;335(26):1933-40

J Am Coll Cardiol. 1999 Oct;34(4):959-65

Cited by 176 citations (total)

Journal Article Review

Cardiac metaiodobenzylguanidine imaging and heart failure.

Electronic publication date June 24, 2014

Search for publications in this journal Curr Heart Fail Rep

Tomoaki Nakata [...] Hirohito Sugawara et al.

The autonomic nervous system has pivotal roles in pathophysiology and prognosis in patients with heart failure. Cardiac (123)I-labeled metaiodobenzylguanidine (MIBG)...

Comparative Study Evaluation Study Journal Article Multicenter Study

Assessment of I-mIBG and Tc-tetrofosmin single-photon emission computed tomographic images for the prediction of arrhythmic events in patients with ischemic heart failure: Intermediate severity innervation defects are associated with higher arrhythmic risk.

Electronic publication date February 27, 2018

Search for publications in this journal J Nucl Cardiol

Mark I Travin [...] Hein J Verberne et al.

RATIONALE

I-mIBG planar image heart-to-mediastinum ratios effectively risk-stratify heart failure (HF) patients. The value of single-photon emission computed tomographic (SPECT) imaging...

Conflict of interest statement

No conflict of interest statement provided.

MeSH

Specialties