Publications

Comparative Study
Journal Article
Ppublish 36 citations
Electronic publication date
October 1, 1992

View on Pubmed.gov 1382898 View on doi.org

Abbott IMx evaluated for assay of prostate-specific antigen in serum.

Search for publications in this journal Clin Chem - 38(10):2140-2

  • A M Dnistrian

    Search for this expert
    1
  • M K Schwartz
  • C A Smith

    Search for this expert
  • J S Nisselbaum

    Search for this expert
  • W R Fair

    Search for this expert

Abstract

We evaluated a new fully automated procedure for quantitative measurement of prostate-specific antigen (PSA) by the Microparticle Enzyme Immunoassay (MEIA) technology developed for the Abbott IMx automated immunoassay system. The performance characteristics of the Abbott IMx PSA assay (y) were evaluated and compared with those of the Hybritech Tandem-E PSA assay (x), a solid-phase two-site immunoenzymometric assay. PSA values for both assays were well correlated (r = 0.99); regression analysis yielded the equation y = 0.92x - 0.23 micrograms/L. The Abbott assay proved reliable and reproducible, as shown by the intra- and interassay coefficients of variation (2.0-3.4% and 3.1-4.7%, respectively). The assay gave a linear standard curve up to 100 micrograms/L and was very sensitive (detected PSA < 0.1 microgram/L). This analytical sensitivity was comparable with that of the Tandem-E PSA assay. Overall, the IMx PSA assay demonstrated the accuracy, precision, linearity, and intermethod correlation required for monitoring patients with prostate cancer.

References

No references provided.

Cited by 36 citations (total)

Comparative Study Journal Article

Quantification of prostate-specific antigen immunoreactivity in human breast cyst fluids.

Electronic publication date January 1, 1996

Search for publications in this journal Breast Cancer Res Treat

F Mannello [...] G Gazzanelli et al.

The frequency of gross cystic breast disease in premenopausal women and its possible association with increased breast cancer risk emphasises...

Journal Article Research Support, N.I.H., Extramural Research Support, N.I.H., Intramural

Ultrasensitive immunosensor for cancer biomarker proteins using gold nanoparticle film electrodes and multienzyme-particle amplification.

Electronic publication date April 7, 2009

Search for publications in this journal ACS Nano

Vigneshwaran Mani [...] James F Rusling et al.

A densely packed gold nanoparticle platform combined with a multiple-enzyme labeled detection antibody-magnetic bead bioconjugate was used as the basis...

Conflict of interest statement

No conflict of interest statement provided.

MeSH

Specialties

Substances