Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation.
- Department of Medicine, University of Ulsan College of Medicine, Cardiac Center, Asan Medical Center, Seoul, Korea.
Abstract
BACKGROUND
Predictors and long-term prognosis of late stent malapposition (LSM) after bare-metal stent (BMS) implantation are unknown.
METHODS AND RESULTS
We evaluated the incidence, mechanisms, predictors, and long-term prognosis of LSM after BMS implantation in 881 patients (992 native lesions) in whom intravascular ultrasound was performed at index and 6-month follow-up. LSM was defined as a separation of stent struts from the intimal surface of the arterial wall that was not presented at stent implantation. LSM occurred in 54 patients with 54 lesions (5.4% overall); the incidence was 10.3% (9 of 87) after directional coronary atherectomy (DCA) before stenting and 11.5% (11 of 96) after primary stenting in acute myocardial infarction (P=0.031 and P=0.007, respectively, versus elective stenting with conventional balloon pre-dilation, 4.3% [30 of 692]). There was an increase of external elastic membrane area (18.9+/-3.9 to 24.5+/-5.1 mm2, P<0.001) that was greater than the increase in plaque area (9.6+/-3.0 to 11.4+/-2.9 mm2, P<0.001). Independent predictors of LSM were primary stenting in acute myocardial infarction (P=0.023, OR=2.55, 95% CI=1.14 to 5.69) and DCA before stenting (P=0.025, OR=3.02, 95% CI=1.15 to 7.96). There were no significant differences in major adverse cardiac events between LSM and non-LSM groups during mean 3-year follow-up (1.9% versus 1.8%, respectively, P=NS).
CONCLUSIONS
LSM occurs in approximately 5% after BMS implantation. The predictors of LSM are primary stenting in acute myocardial infarction and DCA before stenting. Compared with complete stent apposition at follow-up, LSM after BMS implantation is not associated with any major adverse cardiac events during a mean 3-year follow-up after detection of LSM.
References
Cited by 139 citations (total)
Journal Article Validation Study
Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage.
Electronic publication date June 20, 2012
G J Ughi [...] J D'hooge et al.
The implantation of intracoronary stents is currently the standard approach for the treatment of coronary atherosclerotic disease. The widespread adoption...
Journal Article Review
Use of intravascular imaging in managing coronary artery disease.
Electronic publication date July 1, 2014
Sanda Jegere [...] Andrejs Erglis et al.
For many years, coronary angiography has been considered "the gold standard" for evaluating patients with coronary artery disease. However, angiography...