View on Pubmed.gov 15852140 | View on doi.org 10.1039/b501890...
Extraction, interpretation and validation of information for comparing samples in metabolic LC/MS data sets.
- Research Group for Chemometrics, Department of Chemistry, Umeå University, SE-90187 Umeå, Sweden. henrik.antti@chem.umu.se
Abstract
LC/MS is an analytical technique that, due to its high sensitivity, has become increasingly popular for the generation of metabolic signatures in biological samples and for the building of metabolic data bases. However, to be able to create robust and interpretable (transparent) multivariate models for the comparison of many samples, the data must fulfil certain specific criteria: (i) that each sample is characterized by the same number of variables, (ii) that each of these variables is represented across all observations, and (iii) that a variable in one sample has the same biological meaning or represents the same metabolite in all other samples. In addition, the obtained models must have the ability to make predictions of, e.g. related and independent samples characterized accordingly to the model samples. This method involves the construction of a representative data set, including automatic peak detection, alignment, setting of retention time windows, summing in the chromatographic dimension and data compression by means of alternating regression, where the relevant metabolic variation is retained for further modelling using multivariate analysis. This approach has the advantage of allowing the comparison of large numbers of samples based on their LC/MS metabolic profiles, but also of creating a means for the interpretation of the investigated biological system. This includes finding relevant systematic patterns among samples, identifying influential variables, verifying the findings in the raw data, and finally using the models for predictions. The presented strategy was here applied to a population study using urine samples from two cohorts, Shanxi (People's Republic of China) and Honolulu (USA). The results showed that the evaluation of the extracted information data using partial least square discriminant analysis (PLS-DA) provided a robust, predictive and transparent model for the metabolic differences between the two populations. The presented findings suggest that this is a general approach for data handling, analysis, and evaluation of large metabolic LC/MS data sets.
References
Xenobiotica. 1999 Nov;29(11):1181-9
Nat Biotechnol. 2000 Nov;18(11):1157-61
Rapid Commun Mass Spectrom. 2002;16(20):1991-6
Nat Med. 2002 Dec;8(12):1439-44
Cited by 122 citations (total)
Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S.
Nonlinear data alignment for UPLC-MS and HPLC-MS based metabolomics: quantitative analysis of endogenous and exogenous metabolites in human serum.
Electronic publication date May 11, 2007
Anders Nordström [...] Gary Siuzdak et al.
A nonlinear alignment strategy was examined for the quantitative analysis of serum metabolites. Two small-molecule mixtures with a difference in...
Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Research Support, U.S. Gov't, Non-P.H.S. Review
Innovation: Metabolomics: the apogee of the omics trilogy.
Electronic publication date May 12, 2012
Gary J Patti [...] Gary Siuzdak et al.
Metabolites, the chemical entities that are transformed during metabolism, provide a functional readout of cellular biochemistry. With emerging technologies in...
Conflict of interest statement
MeSH
Specialties
- •
- •