Publications

Journal Article Ppublish 47 citations
Electronic publication date
June 30, 2006

View on Pubmed.gov 16681491 | View on doi.org 10.2310/j.6480....

Influence of titanium surface charge on fibroblast adhesion.

Search for publications in this journal Clin Implant Dent Relat Res - 8(1):32-8

Abstract

BACKGROUND

Although dental implants have a high success rate, failure owing to the absence of adhesion between the gingival connective tissue and the implant surface is still being reported.

PURPOSE

This study was designed to evaluate the effect of a titanium surface charge on fibroblast adhesion.

MATERIAL AND METHODS

An electrical chamber was custom-made to generate negative and positive surface charges on commercially pure titanium cylinders with a potential difference of 4.5 V. Twenty-seven titanium cylinders were divided into three experimental groups. In each group, cell attachment to a positively charged titanium cylinder, a negatively charged titanium cylinder, and a titanium cylinder (control) was studied at three time intervals of 15, 30, and 60 minutes. NCTC clone 929 fibroblasts were used in these experiments. The effect of the potential difference in the pH of Dulbecco's Modified Eagle Medium (DMEM) was also evaluated using two new specimens at time intervals of 15, 30, 60, and 80 minutes.

RESULTS

The fibroblast cell attachment was more statistically significant to the positively charged titanium cylinder than the negatively charged titanium cylinder (p =.002) and the control (p=.000), whereas the cell adhesion difference between the control and the negatively charged titanium cylinder was not statistically significant (p=.808). The range of pH difference of the DMEM in the negative and positive parts of the electrical chamber was 0.46 and 0.30, respectively.

CONCLUSION

Within the limitations of this in vitro study, the positive surface charge of the titanium cylinder results in significantly favorable cell adhesion.

References

No references provided.

Cited by 47 citations (total)

Journal Article Research Support, Non-U.S. Gov't

Impedimetric cell-based biosensor for real-time monitoring of cytopathic effects induced by dengue viruses.

Electronic publication date February 18, 2016

Search for publications in this journal Biosens Bioelectron

Ming Soon Cheng [...] Vincent T Chow et al.

We describe an impedimetric cell-based biosensor constructed from poly-l-lysine (PLL)-modified screen-printed carbon electrode for real-time monitoring of dengue virus (DENV)...

Journal Article Research Support, Non-U.S. Gov't Review

Augmenting endogenous repair of soft tissues with nanofibre scaffolds.

Electronic publication date September 26, 2019

Search for publications in this journal J R Soc Interface

Mathew Baldwin [...] Andrew Carr et al.

As our ability to engineer nanoscale materials has developed we can now influence endogenous cellular processes with increasing precision. Consequently,...

Conflict of interest statement

No conflict of interest statement provided.

MeSH

Specialties

Substances