View on Pubmed.gov 18213460 | View on doi.org 10.1007/s00056-...
Impact of implant design on primary stability of orthodontic mini-implants.
- Poliklinik für Kieferorthopädie, Heinrich Heine Universität Düsseldorf, Moorenstrasse 5, Düsseldorf, Germany. wilmes@med.uni-duesseldorf.de
Abstract
AIM
Skeletal anchorage with mini-implants has greatly broadened the treatment possibilities in orthodontics over the last few years. To reduce implant failure rates, it is advisable to obtain adequate primary stability. The aim of this study was to quantitatively analyze the impact of implant design and dimension on primary stability.
MATERIAL AND METHODS
Forty-two porcine iliac bone segments were prepared and embedded in resin. To evaluate the primary stability, we documented insertion torques of the following mini-implants: Aarhus Screw, AbsoAnchor, LOMAS, Micro-Anchorage-System, ORLUS and Spider Screw. In each bone, five Dual Top Screws were inserted for reference purposes to achieve comparability among the specimens.
RESULTS
We observed wide variation in insertion torques and hence primary stability, depending on mini-implant design and dimension; the great impact that mini-implant diameter has on insertion torques was particularly conspicuous. Conical mini-implants achieved higher primary stabilities than cylindrical designs.
CONCLUSIONS
The diameter and design of the mini-implant thread have a distinctive impact on primary stability. Depending on the region of insertion and local bone quality, the choice of the mini-implant design and size is crucial to establish sufficient primary stability.
References
Cited by 170 citations (total)
Journal Article Review
A Mini-review on the Effect of Mini-implants on Contemporary Orthodontic Science.
Electronic publication date August 1, 2015
Saeid Nosouhian [...] Amin Davoudi et al.
The purpose of this literature review was to screen the valuable published articles regarding to the impacts of mini-implants on...
Journal Article Research Support, Non-U.S. Gov't
Bone quality affects stability of orthodontic miniscrews.
Electronic publication date March 11, 2022
Wan-Ping Yu [...] Jui-Ting Hsu et al.
The objective of this study was to evaluate the effect of bone-miniscrew contact percentage (BMC%) and bone quality and quantity...