Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging.

Search for publications in this journal JACC Cardiovasc Imaging - 1(6):752-61

Abstract

OBJECTIVES

We present the first clinical experience with intracoronary optical frequency domain imaging (OFDI) in human patients.

BACKGROUND

Intracoronary optical coherence tomography (OCT) is a catheter-based optical imaging modality that is capable of providing microscopic (approximately 7-microm axial resolution, approximately 30-microm transverse resolution), cross-sectional images of the coronary wall. Although the use of OCT has shown substantial promise for imaging coronary microstructure, blood attenuates the OCT signal, necessitating prolonged, proximal occlusion to screen long arterial segments. OFDI is a second-generation form of OCT that is capable of acquiring images at much higher frame rates. The increased speed of OFDI enables rapid, 3-dimensional imaging of long coronary segments after a brief, nonocclusive saline purge.

METHODS

Volumetric OFDI images were obtained in 3 patients after intracoronary stent deployment. Imaging was performed in the left anterior descending and right coronary arteries with the use of a nonocclusive saline purge rates ranging from 3 to 4 ml/s and for purge durations of 3 to 4 s. After imaging, the OFDI datasets were segmented using previously documented criteria and volume rendered.

RESULTS

Good visualization of the artery wall was obtained in all cases, with clear viewing lengths ranging from 3.0 to 7.0 cm at pullback rates ranging from 5 to 20 mm/s. A diverse range of microscopic features were identified in 2 and 3 dimensions, including thin-capped fibroatheromas, calcium, macrophages, cholesterol crystals, bare stent struts, and stents with neointimal hyperplasia. There were no complications of the OFDI procedure.

CONCLUSIONS

Our results demonstrate that OFDI is a viable method for imaging the microstructure of long coronary segments in patients. Given its ability to provide microscopic information in a practical manner, this technology may be useful for studying human coronary pathophysiology in vivo and as a clinical tool for guiding the management of coronary artery disease.

References

J Biomed Opt. 2006 Mar-Apr;11(2):021002

J Am Coll Cardiol. 2002 Feb 20;39(4):604-9

Eur Heart J. 2006 Aug;27(15):1763

Circulation. 2002 Oct 29;106(18):2409-10

Cited by 324 citations (total)

Journal Article Review

Intracoronary optical coherence tomography: a comprehensive review clinical and research applications.

Electronic publication date January 28, 2010

Search for publications in this journal JACC Cardiovasc Interv

Hiram G Bezerra [...] Daniel I Simon et al.

Cardiovascular optical coherence tomography (OCT) is a catheter-based invasive imaging system. Using light rather than ultrasound, OCT produces high-resolution in...

Journal Article Validation Study

Automatic segmentation of in-vivo intra-coronary optical coherence tomography images to assess stent strut apposition and coverage.

Electronic publication date June 20, 2012

Search for publications in this journal Int J Cardiovasc Imaging

G J Ughi [...] J D'hooge et al.

The implantation of intracoronary stents is currently the standard approach for the treatment of coronary atherosclerotic disease. The widespread adoption...

Conflict of interest statement

No conflict of interest statement provided.

MeSH