Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research.
- Dipartimento di Neuroscienze, Sezione Neurologia, Università di Siena, Italy. Electronic address: rossisimo@unisi.it.
- Human Motor Control Section, NINDS, NIH, Bethesda, USA.
- Università Campus Biomedico, Roma, Italy; Casa di Cura S. Raffaele, Cassino, Italy.
- Berenson-Allen Center for Noninvasive Brain Stimulation, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, USA.
Safety of TMS Consensus Group
Abstract
This article is based on a consensus conference, which took place in Certosa di Pontignano, Siena (Italy) on March 7-9, 2008, intended to update the previous safety guidelines for the application of transcranial magnetic stimulation (TMS) in research and clinical settings. Over the past decade the scientific and medical community has had the opportunity to evaluate the safety record of research studies and clinical applications of TMS and repetitive TMS (rTMS). In these years the number of applications of conventional TMS has grown impressively, new paradigms of stimulation have been developed (e.g., patterned repetitive TMS) and technical advances have led to new device designs and to the real-time integration of TMS with electroencephalography (EEG), positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). Thousands of healthy subjects and patients with various neurological and psychiatric diseases have undergone TMS allowing a better assessment of relative risks. The occurrence of seizures (i.e., the most serious TMS-related acute adverse effect) has been extremely rare, with most of the few new cases receiving rTMS exceeding previous guidelines, often in patients under treatment with drugs which potentially lower the seizure threshold. The present updated guidelines review issues of risk and safety of conventional TMS protocols, address the undesired effects and risks of emerging TMS interventions, the applications of TMS in patients with implanted electrodes in the central nervous system, and safety aspects of TMS in neuroimaging environments. We cover recommended limits of stimulation parameters and other important precautions, monitoring of subjects, expertise of the rTMS team, and ethical issues. While all the recommendations here are expert based, they utilize published data to the extent possible.
References
Neurol Res. 2001 Jun;23(4):343-6
IEEE Trans Biomed Eng. 2003 Sep;50(9):1074-85
J Neurol Neurosurg Psychiatry. 2005 Dec;76(12):1614-23
Clin Neurophysiol. 2007 Nov;118(11):2506-11
Cited by 5080 citations (total)
Journal Article Randomized Controlled Trial Research Support, Non-U.S. Gov't
Random noise stimulation improves neuroplasticity in perceptual learning.
Electronic publication date December 20, 2011
Anna Fertonani [...] Carlo Miniussi et al.
Perceptual learning is considered a manifestation of neural plasticity in the human brain. We investigated brain plasticity mechanisms in a...
Journal Article Meta-Analysis Research Support, Non-U.S. Gov't
Visual selection and the human frontal eye fields: effects of frontal transcranial magnetic stimulation on partial report analyzed by Bundesen's theory of visual attention.
Electronic publication date December 24, 2011
June Hung [...] Vincent Walsh et al.
While the frontal eye fields (FEF) are traditionally associated with eye movements, recent work indicates possible roles in controlling selective...
Conflict of interest statement
MeSH
- •
- •
- •
- •
Specialties
- •
- •
- •
- •