Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at jimma university specialized hospital, southwest ethiopia.

Search for publications in this journal Ethiop J Health Sci - 21(1):9-17

Abstract

BACKGROUND

Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital.

METHODS

A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher.

RESULTS

The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively.

CONCLUSION

Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.

References

Am J Med Qual. 2009 Jan-Feb;24(1):45-52

Am J Infect Control. 2008 Dec;36(10):727-31

Am J Infect Control. 2007 Oct;35(8):527-30

J Hosp Infect. 2000 Dec;46(4):241-56

Cited by 38 citations (total)

Journal Article Research Support, Non-U.S. Gov't

Indoor air bacterial load and antibiotic susceptibility pattern of isolates at Adare General Hospital in Hawassa, Ethiopia.

Electronic publication date December 1, 2023

Search for publications in this journal Front Public Health

Yibeltal Assefa Atalay [...] Kelemu Abebe Gelaw et al.

Background

Air is the agent of pathogenic microbes that cause significant problems in the hospital environment. Multidrug resistance poses a major...

Journal Article Research Support, Non-U.S. Gov't

Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital.

Electronic publication date July 17, 2014

Search for publications in this journal Ann Clin Microbiol Antimicrob

Teklu Shiferaw [...] Tsegaye Sewunet et al.

INTRODUCTION

Hospital acquired infections are recognized as critical public health problems. Infections are frequently caused by organisms residing in healthcare environment,...

Conflict of interest statement