View on Pubmed.gov 24045140 | View on doi.org 10.1016/j.jamco...
Outcomes of synthetic mesh in contaminated ventral hernia repairs.
- Hernia Center, Division of Minimal Access and Bariatric Surgery, Greenville Hospital System University Medical Center, Greenville, SC. Electronic address: acarbonell@ghs.org.
Abstract
BACKGROUND
Given the questionable long-term durability of biologic meshes, additional prosthetic options for ventral hernia repairs (VHR) in contaminated fields are necessary. Recent evidence suggests improved bacterial resistance of reduced-weight, large-pore synthetics, giving a potential mesh alternative for repair of contaminated hernias. We aimed to evaluate the clinical outcomes of 2 institutions' experience implanting lightweight polypropylene synthetic mesh in clean-contaminated and contaminated fields.
STUDY DESIGN
Open VHRs performed with polypropylene mesh in the retro-rectus position in clean-contaminated and contaminated fields were evaluated. Primary outcomes parameters included surgical site infection, surgical site occurrence, mesh removal, and hernia recurrence.
RESULTS
One hundred patients (50 male, 50 female) with a mean age of 60 ± 13 years and a mean body mass index (calculated as kg/m(2)) of 32 ± 9.3 met inclusion criteria. There were 42 clean-contaminated and 58 contaminated cases. The incidence of surgical site occurrence was 26.2% in clean-contaminated cases and 34% in contaminated cases. The 30-day surgical site infection rate was 7.1% for clean-contaminated cases and 19.0% for contaminated cases. There were a total of 7 recurrences with a mean follow-up of 10.8 ± 9.9 months (range 1 to 63 months). Mesh removal was required in 4 patients: 2 due to early anastomotic leaks, 1 due to stomal disruption and retraction in a morbidly obese patient, and 1 from a long-term enterocutaneous fistula.
CONCLUSIONS
Although perhaps not yet considered standard of care in the United States, we have demonstrated favorable infection, recurrence, and mesh removal rates associated with the use of synthetic mesh in contaminated VHR.
References
Cited by 308 citations (total)
Journal Article
Temporary abdominal closure with polytetrafluoroethylene prosthetic mesh in critically ill non-trauma patients.
Electronic publication date September 15, 2015
A Robin-Lersundi [...] M A García-Ureña et al.
BACKGROUND
Survival in critically ill non-trauma patients may be improved by performing temporary abdominal closure using different surgical techniques. We describe...
Case Reports Journal Article
Long-term outcome of biologic graft: a case report.
Electronic publication date April 8, 2015
Kim-Phung Nguyen [...] Eddy C Hsueh et al.
INTRODUCTION
Biologic grafts have been shown to support tissue regeneration in various animal models. Very few reports in the literature exist...
Conflict of interest statement
MeSH
- •
- •
- •
- •
- •
- •
Specialties
- •
- •
Substances
Copyright
Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.