Quantitative assessment of left ventricular function by 3-dimensional speckle-tracking echocardiography in patients with chronic heart failure: a meta-analysis.
- Department of Cardiovascular Ultrasound, First Affiliated Hospital of China Medical University, 115 Nanjing St, Heping District, 110001 Shenyang, China. cmu1h_mcy@126.com.
Abstract
OBJECTIVES
To provide a comprehensive analysis of the clinical utility of 3-dimensional (3D) speckle-tracking echocardiography for left ventricular (LV) function in patients with chronic heart failure (CHF).
METHODS
Literature searches were conducted in the PubMed, Embase, Web of Science, and China BioMedicine databases on relevant articles published before October 1, 2012. Crude standardized mean differences with 95% confidence intervals (CIs) were calculated.
RESULTS
Seven case-control studies were included with a total of 375 patients with CHF and 181 healthy control participants. Meta-analysis results showed that the LV ejection fraction in the patients was significantly lower than in the controls (standardized mean difference, -4.62; 95% CI, -6.19 to -3.04), whereas the LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV) in the patients were higher than in the controls (LVEDV: standardized mean difference, 1.76; 95% CI, 1.09 to 2.44; LVESV: standardized mean difference, 2.04, 95% CI, 1.30 to 2.78). The results also indicated that the patients had a greater delay in the standard deviation of the time to peak area tracking and the maximum difference in the time to peak area tracking in the 16 LV segments than the controls (standard deviation of the time to peak area tracking: standardized mean difference, 3.01; 95% CI, 1.73 to 4.29; maximum difference in the time to peak area tracking: standardized mean difference, 3.26; 95% CI, 1.58 to 4.93). Furthermore, global longitudinal, circumferential, and radial strain were also significantly impaired in the patients compared to the controls (longitudinal strain: standardized mean difference, 2.75; 95% CI, 1.11 to 4.39; circumferential strain: standardized mean difference, 2.71; 95% CI, 1.15 to 4.27; radial strain: standardized mean difference, 1.80; 95% CI, 0.45 to 3.14).
CONCLUSIONS
This meta-analysis suggests that LV function in patients with CHF can be noninvasively and objectively measured by 3D speckle-tracking echocardiography.
References
Cited by 20 citations (total)
Comparative Study Journal Article
The impact of preload on 3-dimensional deformation parameters: principal strain, twist and torsion.
Electronic publication date August 7, 2018
Hyo-Suk Ahn [...] Ho-Joong Youn et al.
BACKGROUND
Strain analysis is feasible using three-dimensional (3D) echocardiography. This approach provides various parameters based on speckle tracking analysis from one...
Journal Article Randomized Controlled Trial
Pretreatment with glucose-insulin-potassium improves ventricular performances after coronary artery bypass surgery: a randomized controlled trial.
Electronic publication date June 16, 2021
Marc Licker [...] Christoph Ellenberger et al.
Heart failure is the main cause of poor outcome following open heart surgery and experimental studies have demonstrated that glucose-insulin-potassium...
Conflict of interest statement
MeSH
- •
- •
- •
- •
Specialties
- •
- •