View on Pubmed.gov 25440678 | View on doi.org 10.1016/j.gie.2...
Comparative effectiveness of biliary brush cytology and intraductal biopsy for detection of malignant biliary strictures: a systematic review and meta-analysis.
- Digestive Disease Institute, The Cleveland Clinic, Cleveland, Ohio, USA; Center for Interventional Endoscopy, Orlando, Florida, USA.
- Department of Gastroenterology, Yale University, New Haven, Connecticut, USA.
- Digestive Disease Institute, The Cleveland Clinic, Cleveland, Ohio, USA.
Abstract
BACKGROUND
Evaluation of indeterminate biliary strictures typically involves collection and analysis of tissue or cells. Brush cytology and intraductal biopsies that are routinely performed during ERCP to assess malignant-appearing biliary strictures are limited by relatively low sensitivity.
OBJECTIVE
To study the comparative effectiveness of brushings for cytology and intraductal biopsies in the etiology of biliary strictures.
DESIGN
Meta-analysis.
SETTING
Referral center.
PATIENTS
PUBMED and Embase databases were reviewed for studies published to April 2014 where diagnostic correlation of histology was available.
INTERVENTION
Database and review of study findings.
MAIN OUTCOME MEASUREMENTS
Sensitivity and specificity.
RESULTS
The pooled sensitivity and specificity of brushings for the diagnosis of malignant biliary strictures was 45% (95% confidence interval [CI], 40%-50%) and 99% (95% CI, 98%-100%), respectively. The pooled diagnostic odds ratio to detect malignant biliary strictures was 33.43 (95% CI, 14.29-78.24). For intraductal biopsies, the pooled sensitivity and specificity were 48.1% (95% CI, 42.8%-53.4%) and 99.2% (95% CI, 97.6%-99.8%), respectively. The pooled diagnostic odds ratio to detect malignant biliary strictures was 43.18 (95% CI, 19.39-95.83). A combination of both modalities only modestly increased the sensitivity (59.4%; 95% CI, 53.7%-64.8%) with a specificity of 100% (95% CI, 98.8%-100.0%). The Begg-Mazumdar and Egger tests indicated a low potential for publication bias.
LIMITATIONS
Inclusion of low-quality studies.
CONCLUSION
Our study suggests that both brushings and biopsy are comparable and have limited sensitivity for the diagnosis of malignant biliary strictures. A combination of both only modestly increases the sensitivity.
References
J Surg Res. 2013 Sep;184(1):304-11
Hepatology. 2011 Mar;53(3):875-84
Gastrointest Endosc. 1998 Sep;48(3):288-90
Gastrointest Endosc. 2001 Nov;54(5):587-94
Cited by 455 citations (total)
Journal Article Review
Advanced endoscopic imaging of indeterminate biliary strictures.
Electronic publication date December 18, 2015
James H Tabibian [...] Christopher J Gostout et al.
Endoscopic evaluation of indeterminate biliary strictures (IDBSs) has evolved considerably since the development of flexible fiberoptic endoscopes over 50 years...
Journal Article Review
Recent developments in choledochoscopy: technical and clinical advances.
Electronic publication date June 9, 2016
Ming-Ming Xu [...] Michel Kahaleh et al.
Peroral cholangioscopy has become an important tool in the diagnosis and treatment of a variety of biliary diseases, ranging from...
Conflict of interest statement
MeSH
- •
- •
- •
- •
- •
- •
- •
- •
Specialties
- •
- •
- •
- •
- •
- •
- •
Copyright
Copyright © 2015 American Society for Gastrointestinal Endoscopy. Published by Elsevier Inc. All rights reserved.