View on Pubmed.gov 25598970 | View on doi.org 10.1039/C4RA155...
Development of a microfluidic "click chip" incorporating an immobilized Cu(I) catalyst.
- Radiological Sciences Division, Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 South Kingshighway Blvd., St. Louis, MO 63110, USA.
- Department of Chemical & Biomolecular Engineering, University of Illinois at Urbana-Champaign, 600 S. Mathews Ave., Urbana, IL 61801.
Abstract
We have developed a microfluidic "click chip" incorporating an immobilized Cu(I) catalyst for click reactions. The microfluidic device was fabricated from polydimethylsiloxane (PDMS) bonded to glass and featured ~14,400 posts on the surface to improve catalyst immobilization. This design increased the immobilization efficiency and reduces the reagents' diffusion time to active catalyst site. The device also incorporates five reservoirs to increase the reaction volume with minimal hydrodynamic pressure drop across the device. A novel water-soluble tris-(benzyltriazolylmethyl)amine (TBTA) derivative capable of stabilizing Cu(I), ligand , was synthesized and successfully immobilized on the chip surface. The catalyst immobilized chip surface was characterized by X-ray photoelectron spectroscopy (XPS). The immobilization efficiency was evaluated via radiotracer methods: the immobilized Cu(I) was measured as 1136±272 nmol and the surface immobilized Cu(I) density was 81±20 nmol cm. The active Cu(I)-ligand could be regenerated up to five times without losing any catalyst efficiency. The "click" reaction of Flu568-azide and propargylamine was studied on chip for proof-of-principle. The on-chip reaction yields were ca. 82% with a 50 min reaction time or ca. 55% with a 15 min period at 37 °C, which was higher than those obtained in the conventional reaction. The on-chip "click" reaction involving a biomolecule, cyclo(RGDfK) peptide was also studied and demonstrated a conversion yield of ca. 98%. These encouraging results show promise on the application of the Cu(I) catalyst immobilized "click chip" for the development of biomolecule based imaging agents.
References
Lab Chip. 2009 Aug 21;9(16):2281-5
Anal Chem. 2012 Nov 6;84(21):9446-52
Nature. 2006 Jul 27;442(7101):394-402
Acc Chem Res. 2013 Feb 19;46(2):327-38
Cited by 11 citations (total)
Journal Article Review
Recent Advances in Recoverable Systems for the Copper-Catalyzed Azide-Alkyne Cycloaddition Reaction (CuAAC).
Electronic publication date April 18, 2017
Alessandro Mandoli
The explosively-growing applications of the Cu-catalyzed Huisgen 1,3-dipolar cycloaddition reaction between organic azides and alkynes (CuAAC) have stimulated an impressive...
Journal Article
Diffusion phenomena of cells and biomolecules in microfluidic devices.
Electronic publication date July 17, 2015
Ece Yildiz-Ozturk [...] Ozlem Yesil-Celiktas et al.
Biomicrofluidics is an emerging field at the cross roads of microfluidics and life sciences which requires intensive research efforts in...