Publications

Journal Article Ppublish 32 citations
Electronic publication date
July 12, 2016

View on Pubmed.gov 26341750 | View on doi.org 10.1007/s10549-...

False-negative rate of combined mammography and ultrasound for women with palpable breast masses.

Search for publications in this journal Breast Cancer Res Treat - 153(3):699-702

Abstract

Mammography and ultrasound are often used concurrently for patients with palpable breast masses. While mammography has a false-negative rate of approximately 15 %, the addition of breast ultrasound decreases this rate among patients with palpable breast masses. There are no recent outcome data regarding the use of combined reporting of ultrasound and mammography (CRUM) for palpable breast masses. In this study, female patients presenting with a palpable breast mass were retrospectively reviewed in a prospectively entered database at a single institution from June 2010 to July 2013. All cancer cases and false-negative cases using CRUM were identified. Cancer rates, false-negative rates, and negative predictive values were calculated based on CRUM breast imaging-reporting and data system (BI-RADS) categories. One thousand two hundreds and twelve female patients presenting with a palpable breast mass were identified; 77 % of patients had CRUM and 73 % (682/932) were BI-RADS 1-2. Despite negative or benign BI-RADS, 9.5 % of patients with BI-RADS 1-2 (65/682) underwent biopsy, compared to 96 % of patients with a BI-RADS 4-5 designation. Eighty-one patients were found to have cancers; 2 had BI-RADS 1-2 imaging. The false-negative rate of CRUM was 2.4 % (2/81). Since 69 % (428/617) of BI-RADS 1-2 patients without tissue diagnosis had follow-up imaging and/or clinical exam (median: 27 months, range: 2-62 months) and none developed cancers, the cancer rate and negative predictive value of a palpable breast mass of BI-RADS 1-2 were estimated to be 0.3 % (2/682) and 99.7 %, respectively. In the modern era of combined imaging for breast masses, a patient with a low suspicion exam can be reassured with a negative CRUM report.

References

No references provided.

Cited by 32 citations (total)

Journal Article

The influence of size, depth and histologic characteristics of invasive ductal breast carcinoma on thermographic properties of the breast.

Electronic publication date October 16, 2019

Search for publications in this journal EXCLI J

Marko Mance [...] Milan Miloševic et al.

Invasive breast carcinoma is the most common oncologic disease worldwide. The existing diagnostic methods use morphologic changes in the breast...

Journal Article Practice Guideline Review

ESR Essentials: diagnostic work-up in patients with symptomatic breast disease-practice recommendations by the European Society of Breast Imaging.

Electronic publication date January 31, 2025

Search for publications in this journal Eur Radiol

Alexandra Athanasiou [...] Ritse Mann et al.

Breast complaints are frequent reasons for consultations in primary care or breast clinics. Breast pain, breast lumps, and nipple discharge...

Conflict of interest statement

No conflict of interest statement provided.

MeSH

Specialties