View on Pubmed.gov 27271554 | View on doi.org 10.1007/s00508-...
Radiofrequency catheter ablation versus balloon cryoablation of atrial fibrillation: markers of myocardial damage, inflammation, and thrombogenesis.
- Department of Cardiology, University Medical Centre Ljubljana, Zaloška 2, 1000, Ljubljana, Slovenia. bor.antolic@kclj.si.
- Department of Cardiology, University Medical Centre Ljubljana, Zaloška 2, 1000, Ljubljana, Slovenia.
- Department of Cardiovascular Surgery, University Medical Centre Ljubljana, Zaloška 2, 1000, Ljubljana, Slovenia.
Abstract
BACKGROUND
Evidence from animal and human studies suggests that cryoablation might be associated with a lesser inflammatory response and activation of coagulation compared with radiofrequency ablation. The study was aimed at comparing the effect of cryoballoon and radiofrequency catheter ablation of paroxysmal atrial fibrillation on markers of myocardial damage, inflammation, and activation of coagulation.
METHODS
Forty-one patients received either cryoballoon (n = 23) or radiofrequency (n = 18) ablation of atrial fibrillation. We measured troponin I, high-sensitivity CRP, and interleukin 6 at baseline from the cubital vein, and from the right and left atrium before and after ablation, and from the cubital vein the following day. Prothrombin fragments 1 + 2, soluble P‑selectin, and D‑dimer were measured before and after ablation from both atria.
RESULTS
We observed higher troponin I release in the cryoballoon than in the radiofrequency group (7.01 mcg/l (interquartile range [IQR]: 5.30-9.09) vs 2.32 mcg/l (IQR: 1.45-2.98), p < 0.001). The levels of inflammatory markers (high-sensitivity CRP and interleukin 6) in the two groups were comparable, as were the levels of markers of coagulation activation. Procedure duration, fluoroscopy times, and mid-term success (23 months, IQR 7-32) of the two groups were also comparable.
CONCLUSIONS
Cryoballoon ablation of atrial fibrillation causes more significant myocardial damage, that is, more extensive ablation lesions, compared with radiofrequency catheter ablation. However, no major differences between these two ablation techniques with regard to the inflammatory response and activation of the coagulation system were observed.
References
Eur Heart J. 2005 Oct;26(20):2083-92
J Clin Pathol. 2002 Feb;55(2):152-3
J Clin Pathol. 2005 Apr;58(4):382-8
J Am Coll Cardiol. 2008 Jul 22;52(4):273-8
Cited by 21 citations (total)
Comparative Study Journal Article Randomized Controlled Trial Research Support, Non-U.S. Gov't
Effects of different ablation strategies on long-term left atrial function in patients with paroxysmal atrial fibrillation: a single-blind randomized controlled trial.
Electronic publication date October 23, 2020
Ling You [...] Ruiqin Xie et al.
Restoration of sinus rhythm in atrial fibrillation (AF) by radiofrequency catheter ablation (RFCA) is associated with a transient stunning of...
Journal Article Review
Unveiling the Role of Endothelial Dysfunction: A Possible Key to Enhancing Catheter Ablation Success in Atrial Fibrillation.
Electronic publication date February 26, 2024
George E Zakynthinos [...] Gerasimos Siasos et al.
Atrial fibrillation, a prevalent type of arrhythmia, is increasingly contributing to the economic burden on healthcare systems. The development of...
Conflict of interest statement
MeSH
- •
- •
- •
- •
- •
- •
- •
Specialties
- •
- •
- •
- •
- •
- •
- •
- •
- •
Substances
- •
- •