View on Pubmed.gov 27452954 | View on doi.org 10.1016/j.surg....
Comparative analysis of biologic versus synthetic mesh outcomes in contaminated hernia repairs.
- Case Comprehensive Hernia Center, Department of Surgery, University Hospitals Case Medical Center, Cleveland, OH.
- Division of Minimally Invasive and Bariatric Surgery, Department of Surgery, Penn State University Hershey Medical Center, Hershey, PA.
- Department of General Surgery, Anne Arundel Medical Center, Annapolis, MD.
- Case Comprehensive Hernia Center, Department of Surgery, University Hospitals Case Medical Center, Cleveland, OH. Electronic address: yuri.novitsky@uhhospitals.org.
Abstract
BACKGROUND
Contaminated operative fields pose significant challenges for surgeons performing ventral hernia repair. Although biologic meshes have been utilized increasingly in these fields, recent evidence suggests that synthetic meshes represent a viable option. We analyzed the outcomes of biologic and synthetic mesh utilized in patients undergoing major ventral hernia repair in clean-contaminated/contaminated fields.
METHODS
We conducted a multicenter, retrospective review of patients undergoing open ventral hernia repair in clean-contaminated/contaminated fields using biologic or synthetic mesh. Patient and hernia details were characterized. Primary outcomes included 90-day surgical site event, surgical site infection, and hernia recurrence.
RESULTS
A total of 126 patients undergoing major ventral hernia repair in clean-contaminated/contaminated fields (69 biologic and 57 synthetic meshes) were analyzed. Groups were similar in both patient and hernia characteristics. There were 13 (22.8%) surgical site events in the synthetic cohort compared to 29 (42.0%) in the biologic cohort, PÂ =Â .024. Similarly, surgical site infections were less frequent in the synthetic group, with 7 (12.3%) vs 22 (31.9%), PÂ =Â .01. With a mean follow-up of 20Â months, there were more recurrences in the biologic group: 15 (26.3%) vs 4 (8.9%) in the synthetic group, PÂ =Â .039.
CONCLUSION
The choice of mesh for clean-contaminated/contaminated ventral hernia repair remains debatable. We demonstrated that using synthetic sublay mesh resulted in a significantly lower wound morbidity and more durable outcomes versus a similar cohort of biologic repairs. This is likely secondary to improved bacterial clearance and faster integration of macroporous synthetics. Overall, our findings not only support suitability of synthetic mesh in contaminated settings but also challenge the purported advantage of biologics in clean-contaminated/contaminated ventral hernia repairs.
References
Cited by 145 citations (total)
Journal Article Meta-Analysis Systematic Review
Is there a role for prophylactic mesh in abdominal wall closure after emergency laparotomy? A systematic review and meta-analysis.
Electronic publication date April 21, 2021
F A Burns [...] Matthew J Lee et al.
BACKGROUND
Incisional hernias are a common complication of emergency laparotomy and are associated with significant morbidity. Recent studies have found a...
Journal Article
When the Mesh Goes Away: An Analysis of Poly-4-Hydroxybutyrate Mesh for Complex Hernia Repair.
Electronic publication date January 17, 2020
Charles A Messa [...] John P Fischer et al.
Conflict of interest statement
MeSH
- •
- •
- •
- •
Specialties
- •
- •
Substances
- •
Copyright
Copyright © 2016 Elsevier Inc. All rights reserved.