View on Pubmed.gov 28212858 | View on doi.org 10.1016/j.bbame...
Refractive index and thickness determination in Langmuir monolayers of myelin lipids.
- Centro de Investigaciones en QuÃmica Biológica de Córdoba (CIQUIBIC-CONICET) - Departamento de QuÃmica Biológica, Facultad de Ciencias QuÃmicas, Universidad Nacional de Córdoba, Ciudad Universitaria, X5000HUA, Córdoba, Argentina.
- Brazilian Synchrotron Light Laboratory - LNLS, CNPEM, Rua Giuseppe Maximo Scolfaro, 10000, Campinas, SP 13083-070, Brazil.
- Centro de Investigaciones en QuÃmica Biológica de Córdoba (CIQUIBIC-CONICET) - Departamento de QuÃmica Biológica, Facultad de Ciencias QuÃmicas, Universidad Nacional de Córdoba, Ciudad Universitaria, X5000HUA, Córdoba, Argentina. Electronic address: oliveira@fcq.unc.edu.ar.
Abstract
Langmuir monolayers at the air/water interface are widely used as biomembrane models and for amphiphilic molecules studies in general. Under controlled intermolecular organization (lateral molecular area), surface pressure, surface potential, reflectivity (R) and other magnitudes can be precisely determined on these planar monomolecular films. However, some physical parameters such as the refractive index of the monolayer (n) still remain elusive. The refractive index is very relevant because (in combination with R) it allows for the determination of the thickness of the film. The uncertainties of n determine important errors that propagate non-linearly into the calculation of monolayers thickness. Here we present an analytical method for the determination of n in monolayers based on refractive index matching. By using a Brewster angle microscopy (BAM) setup and monolayers spread over subphases with variable refractive index (n), a minimum in R is search as a function of n. In these conditions, n equals n. The results shown correspond to monolayers of myelin lipids. The n values remain constant at 1.46 upon compression and equals the obtained value for myelin lipid bilayers in suspension. The values for n and R allow for the determination of thickness. We establish comparisons between these thicknesses for the monolayer and those obtained from two X-ray scattering techniques: 1) GIXOS for monolayers at the air/water interface and 2) SAXS for bilayers in bulk suspension. This allows us to conclude that the thickness that we measure by BAM includes the apolar and polar headgroup regions of the monolayer.
References
Cited by 38 citations (total)
Journal Article
Practical considerations for birefringence microscopy of myelin structure: Microscope design and tissue processing for effective imaging.
Electronic publication date January 1, 2024
Nathan Blanke [...] Irving J Bigio et al.
Despite the interest in studying and quantifying the structural integrity of myelin in postmortem brain tissue, current methods for high-resolution...
Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Review
Whole-Brain Profiling of Cells and Circuits in Mammals by Tissue Clearing and Light-Sheet Microscopy.
Electronic publication date August 25, 2020
Hiroki R Ueda [...] Philipp J Keller et al.
Tissue clearing and light-sheet microscopy have a 100-year-plus history, yet these fields have been combined only recently to facilitate novel...
Conflict of interest statement
MeSH
- •
- •
Specialties
- •
- •
- •
Substances
Copyright
Copyright © 2017 Elsevier B.V. All rights reserved.