Publications

Journal Article
Research Support, Non-U.S. Gov't
Ppublish 38 citations
Electronic publication date
September 1, 2017

View on Pubmed.gov 28212858 | View on doi.org 10.1016/j.bbame...

Refractive index and thickness determination in Langmuir monolayers of myelin lipids.

Search for publications in this journal Biochim Biophys Acta Biomembr - 1859(5):924-930

Abstract

Langmuir monolayers at the air/water interface are widely used as biomembrane models and for amphiphilic molecules studies in general. Under controlled intermolecular organization (lateral molecular area), surface pressure, surface potential, reflectivity (R) and other magnitudes can be precisely determined on these planar monomolecular films. However, some physical parameters such as the refractive index of the monolayer (n) still remain elusive. The refractive index is very relevant because (in combination with R) it allows for the determination of the thickness of the film. The uncertainties of n determine important errors that propagate non-linearly into the calculation of monolayers thickness. Here we present an analytical method for the determination of n in monolayers based on refractive index matching. By using a Brewster angle microscopy (BAM) setup and monolayers spread over subphases with variable refractive index (n), a minimum in R is search as a function of n. In these conditions, n equals n. The results shown correspond to monolayers of myelin lipids. The n values remain constant at 1.46 upon compression and equals the obtained value for myelin lipid bilayers in suspension. The values for n and R allow for the determination of thickness. We establish comparisons between these thicknesses for the monolayer and those obtained from two X-ray scattering techniques: 1) GIXOS for monolayers at the air/water interface and 2) SAXS for bilayers in bulk suspension. This allows us to conclude that the thickness that we measure by BAM includes the apolar and polar headgroup regions of the monolayer.

References

No references provided.

Cited by 38 citations (total)

Journal Article

Practical considerations for birefringence microscopy of myelin structure: Microscope design and tissue processing for effective imaging.

Electronic publication date January 1, 2024

Search for publications in this journal Imaging Neurosci (Camb)

Nathan Blanke [...] Irving J Bigio et al.

Despite the interest in studying and quantifying the structural integrity of myelin in postmortem brain tissue, current methods for high-resolution...

Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Review

Whole-Brain Profiling of Cells and Circuits in Mammals by Tissue Clearing and Light-Sheet Microscopy.

Electronic publication date August 25, 2020

Search for publications in this journal Neuron

Hiroki R Ueda [...] Philipp J Keller et al.

Tissue clearing and light-sheet microscopy have a 100-year-plus history, yet these fields have been combined only recently to facilitate novel...

Conflict of interest statement

No conflict of interest statement provided.

MeSH

Specialties

Substances

Copyright

Copyright © 2017 Elsevier B.V. All rights reserved.