View on Pubmed.gov 28920574 | View on doi.org 10.2807/1560-79...
Status, quality and specific needs of Zika virus (ZIKV) diagnostic capacity and capability in National Reference Laboratories for arboviruses in 30 EU/EEA countries, May 2016.
- Department of Viroscience, Erasmus University Medical Centre, Rotterdam, the Netherlands.
- European Centre for Disease Prevention and Control, Stockholm, Sweden.
- Netherlands Centre for Infectious Disease Control, Bilthoven, the Netherlands.
ZIKV reference laboratory group
- Stephan Aberle,
- Marjan Van Esbroeck,
- Iva Christova,
- Tatjana Vilibic-Cavlek,
- Jan Richter,
- Hana Zelena,
- Helena Jirincova,
- Anders Fomsgaard,
- Rita Peetso,
- Anne J Jääskeläinen,
- Segolene Brichler,
- Christine Bigaillon,
- Marina Illiaquer,
- Salim Gaba,
- Geraldine Gonfrier,
- Christophe Ramière,
- Isabelle Leparc-Goffart,
- Jean-Dominique Poveda,
- D Hober,
- H Fleury,
- Samira Fafi-Kremer,
- V Foulongne,
- Cécile Henquell,
- Nicolas Leveque,
- Marie Josee Carles,
- J M Mansuy,
- Jonas Schmidt-Chanasit,
- Andreas Nitsche,
- Anna Papa,
- Andreas Mentis,
- Mária Takács,
- Arthur Löve,
- Jeff Connell,
- Giulietta Venturi,
- Jelena Storoženko,
- Algirdas Griskevicius,
- Matthias Opp,
- Christopher Barbara,
- Chantal Reusken,
- Johan Reimerink,
- Susanne Gjeruldsen Dudman,
- Katarzyna Pancer,
- Maria J Alves,
- Cornelia S Ceianu,
- Elena Tichá,
- Tatjana Avšič Županc,
- Maria Paz Sanchez-Seco,
- Thomas Tolfvenstam,
- Emma Aarons.
Abstract
With international travel, Zika virus (ZIKV) is introduced to Europe regularly. A country's ability to robustly detect ZIKV introduction and local transmission is important to minimise the risk for a ZIKV outbreak. Therefore, sufficient expertise and diagnostic capacity and capability are required in European laboratories. To assess the capacity, quality, operational specifics (guidelines and algorithms), technical and interpretation issues and other possible difficulties that were related to ZIKV diagnostics in European countries, a questionnaire was conducted among national reference laboratories in 30 countries in the European Union/European Economic Area (EU/EEA) in May 2016. While the coverage and capacity of ZIKV diagnostics in the EU/EEA national reference laboratories were found to be adequate, the assessment of the quality and needs indicated several crucial points of improvement that will need support at national and EU/EEA level to improve ZIKV preparedness, response and EU/EEA ZIKV surveillance activities.
References
Ann Intern Med. 2017 Jan 17;166(2):99-108
J Clin Microbiol. 2017 Nov;55(11):3219-3226
Ann Lab Med. 2017 Sep;37(5):365-370
EBioMedicine. 2016 Jul;9:250-256
Cited by 13 citations (total)
Journal Article
Zika virus threshold determines transmission by European mosquitoes.
Electronic publication date December 18, 2019
Marie Vazeille [...] Anna-Bella Failloux et al.
Since its emergence in Yap Island in 2007, Zika virus (ZIKV) has affected all continents except Europe. Despite the hundreds...
Journal Article Research Support, Non-U.S. Gov't
Variable Sensitivity in Molecular Detection of Zika Virus in European Expert Laboratories: External Quality Assessment, November 2016.
Electronic publication date June 7, 2018
Remi Charrel [...] Chantal B Reusken et al.
Zika virus (ZIKV) infections are a significant public health concern. A strong capability for ZIKV detection is an absolute requirement...
Conflict of interest statement
MeSH
- •
- •
- •
- •
- •
Specialties
- •
- •
Copyright