The Advantages of Viscous Dissipation Rate over Simplified Power Loss as a Fontan Hemodynamic Metric.
Ann Biomed Eng 46(3):404-416
Authors: Zhenglun Alan Wei, Michael Tree, Phillip M Trusty, Wenjun Wu, Shelly Singh-Gryzbon, Ajit Yoganathan
Affiliations
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA.
- Institute of Computational Science and Cardiovascular Disease, Nanjing Medical University, Nanjing, China.
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA.
- Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, 30332, USA.
Abstract
Flow efficiency through the Fontan connection is an important factor related to patient outcomes. It can be quantified using either a simplified power loss or a viscous dissipation rate metric. Though practically equivalent in simplified Fontan circulation models, these metrics are not identical. Investigation is needed to evaluate the advantages and disadvantages of these metrics for their use in in vivo or more physiologically-accurate Fontan modeling. Thus, simplified power loss and viscous dissipation rate are compared theoretically, computationally, and statistically in this study. Theoretical analysis was employed to assess the assumptions made for each metric and its clinical calculability. Computational simulations were then performed to obtain these two metrics. The results showed that apparent simplified power loss was always greater than the viscous dissipation rate for each patient. This discrepancy can be attributed to the assumptions derived in theoretical analysis. Their effects were also deliberately quantified in this study. Furthermore, statistical analysis was conducted to assess the correlation between the two metrics. Viscous dissipation rate and its indexed quantity show significant, strong, linear correlation to simplified power loss and its indexed quantity (p < 0.001, r > 0.99) under certain assumptions. In conclusion, viscous dissipation rate was found to be more advantageous than simplified power loss as a hemodynamic metric because of its lack of limiting assumptions and calculability in the clinic. Moreover, in addition to providing a time-averaged bulk measurement like simplified power loss, viscous dissipation rate has spatial distribution contours and time-resolved values that may provide additional clinical insight. Finally, viscous dissipation rate could maintain the relationship between Fontan connection flow efficiency and patient outcomes found in previous studies. Consequently, future Fontan hemodynamic studies should calculate both simplified power loss and viscous dissipation rate to maintain ties to previous studies, but also provide the most accurate measure of flow efficiency. Additional attention should be paid to the assumptions required for each metric.
MeSH
Hemodynamics, Biomedical Engineering
Cited by
- Virtual surgery to predict optimized conduit size for adult Fontan patients with 16-mm conduits. Interdiscip Cardiovasc Thorac Surg, 2023
- The impact of blood viscosity modeling on computational fluid dynamic simulations of pediatric patients with Fontan circulation. Phys Fluids (1994), 2024
- Fluid-Structure Interaction Simulation of an Intra-Atrial Fontan Connection. Biology (Basel), 2020
- Haemodynamic performance of 16-20-mm extracardiac Goretex conduits in adolescent Fontan patients at rest and during simulated exercise. Eur J Cardiothorac Surg, 2023
- The first cohort of prospective Fontan surgical planning patients with follow-up data: How accurate is surgical planning? J Thorac Cardiovasc Surg, 2020
- The effect of respiration-driven flow waveforms on hemodynamic metrics used in Fontan surgical planning. J Biomech, 2019
- Non-Newtonian Effects on Patient-Specific Modeling of Fontan Hemodynamics. Ann Biomed Eng, 2021
- Analysis of Inlet Velocity Profiles in Numerical Assessment of Fontan Hemodynamics. Ann Biomed Eng, 2020
- Evolving hemodynamics in Fontan circulation: age-driven insights in patients with interrupted inferior vena cava and hepatoazygos shunt. Am J Physiol Heart Circ Physiol, 2025
- Computational Fluid Dynamics Assessment Associated with Transcatheter Heart Valve Prostheses: A Position Paper of the ISO Working Group. Cardiovasc Eng Technol, 2019
- Computational Investigation of Anastomosis Options of a Right-Heart Pump to Patient Specific Pulmonary Arteries. Ann Biomed Eng, 2022
- Comparison of Fontan Surgical Options for Patients with Apicocaval Juxtaposition. Pediatr Cardiol, 2020