Different Heart Rate Patterns During Cardio-Pulmonary Exercise (CPX) Testing in Individuals With Type 1 Diabetes.
- Exercise Physiology, Training Therapy & Training Research Group, Institute of Sports Sciences, University of Graz, Graz, Austria.
- Division of Diabetology & Metabolism, Department of Internal Medicine, Medical University of Graz, Graz, Austria.
- Diabetes Research Group, School of Medicine, Swansea University, Swansea, United Kingdom.
- Applied Sport, Technology, Exercise and Medicine Research Centre (A-STEM), College of Engineering, Swansea University, Swansea, United Kingdom.
- Sports Science Laboratory, Institute of Health and Tourism Management, FH JOANNEUM-University of Applied Sciences, Bad Gleichenberg, Austria.
Abstract
To investigate the heart rate during cardio-pulmonary exercise (CPX) testing in individuals with type 1 diabetes (T1D) compared to healthy (CON) individuals. Fourteen people (seven individuals with T1D and seven CON individuals) performed a CPX test until volitional exhaustion to determine the first and second lactate turn points (LTP and LTP), ventilatory thresholds (VT and VT), and the heart rate turn point. For these thresholds cardio-respiratory variables and percentages of maximum heart rate, heart rate reserve, maximum oxygen uptake and oxygen uptake reserve, and maximum power output were compared between groups. Additionally, the degree and direction of the deflection of the heart rate to performance curve (k) were compared between groups. Individuals with T1D had similar heart rate at LTP (mean difference) -11, [(95% confidence interval) -27 to 4 b.min], at VT (-12, -8 to 33 b.min) and at LTP (-7, -13 to 26 b.min), at VT (-7, -13 to 28 b.min), and at the heart rate turn point (-5, -14 to 24 b.min) ( = 0.22). Heart rate expressed as percentage of maximum heart rate at LTP, VT, LTP, VT and the heart rate turn point as well as expressed as percentages of heart rate reserve at LTP, VT and the heart rate turn point was lower in individuals with T1D ( < 0.05). k was lower in T1D compared to CON individuals (0.11 ± 0.25 vs. 0.51 ± 0.32, = 0.02). Our findings demonstrate that there are clear differences in the heart rate response during CPX testing in individuals with T1D compared to CON individuals. We suggest using submaximal markers to prescribe exercise intensity in people with T1D, as the heart rate at thresholds is influenced by k. NCT02075567 (https://clinicaltrials.gov/ct2/show/NCT02075567).
References
J Sci Med Sport. 2010 Jan;13(1):74-9
Med Sci Sports Exerc. 1997 Aug;29(8):1040-7
Med Sci Sports Exerc. 2011 Jul;43(7):1334-59
PLoS One. 2015 Aug 28;10(8):e0136489
Cited by 10 citations (total)
Journal Article Review
Exercise Testing in Individuals With Diabetes, Practical Considerations for Exercise Physiologists.
Electronic publication date October 16, 2019
Christophe Kosinski [...] Francesca Amati et al.
Exercise and sports activities are crucial for individuals with diabetes. Diabetic patients are often referred to sports clinics for cardiopulmonary...
Journal Article
Influence of Complications of Diabetes Mellitus on Exercise Tolerance of Patients with Heart Failure: Focusing on autonomic nervous activity and heart rate response during cardiopulmonary exercise tests.
Electronic publication date February 6, 2020
Kodai Ishihara [...] Akira Tamaki et al.
PURPOSE
The purpose of this study was to clarify the influence of complications of diabetes on the exercise tolerance of patients...
Conflict of interest statement
MeSH
- •
- •
- •
- •
- •
- •
Specialties
- •
- •
- •
- •