View on Pubmed.gov 31248799 | View on doi.org 10.1053/j.jvca....
Qualitative Assessment of Color M-Mode Signals in the Evaluation of Left Ventricular Diastolic Function: A Proof of Concept Study.
- Cardiovascular Medicine Division, University of Puerto Rico School of Medicine, San Juan, Puerto Rico. Electronic address: dagmar.hernandez@upr.edu.
- Division of Cardiovascular Medicine, Department of Medicine, Yale University School of Medicine, New Haven, CT.
- Division of Cardiovascular Health and Disease, University of Cincinnati College of Medicine, Cincinnati, OH.
- Division of Cardiovascular and Thoracic Anesthesiology, Mayo Clinic, Phoenix, AZ.
- Cardiovascular Medicine Division, University of Puerto Rico School of Medicine, San Juan, Puerto Rico.
Abstract
OBJECTIVES
Although the most recent American Society of Echocardiography guidelines are a major step forward in echocardiographic evaluation of diastolic function, the ability to differentiate between normal and abnormal function remains challenging. The authors aimed to determine whether qualitative assessments of color M-mode flow displays could be a useful parameter in the evaluation of left ventricular (LV) diastolic dysfunction.
DESIGN
Retrospective observational study.
SETTING
Tertiary care level hospital.
PARTICIPANTS
The study comprised echocardiographic data from 105 consecutive patients.
INTERVENTION
None.
MEASUREMENTS AND MAIN RESULTS
Patients were allocated into the following 3 groups according to the LV diastolic function based on current American Society of Echocardiography recommendation guidelines for LV diastolic dysfunction classification: group I-normal function (n = 40); group II-early relaxation abnormalities (grade I) (n = 50), and group III-elevated LV pressures (grade II) (n = 15). Patients with normal diastolic function were younger (45 ± 14 y) than those with diastolic dysfunction (group II: 64 ± 10 y and group III: 56 ± 15 y) (p < 0.05). Volumetric echocardiographic parameters and mitral inflow and mitral annulus tissue Doppler imaging measures were significantly different among the 3 studied groups (p < 0.05). Interestingly, qualitative assessment of color M-mode flows displayed distinctive signals based on the left ventricle filling properties. Intraobserver and interobserver variability to determine the reliability of these signals were robust (weighted kappa 0.84 ± 0.11 and 0.65 ± 0.13, respectively).
CONCLUSION
Qualitative assessment of color M-mode flow displays offers simple and reliable information of potential usefulness in the evaluation of LV diastolic function.
References
Circulation. 2000 May 2;101(17):2118-21
Circulation. 2002 Mar 19;105(11):1387-93
Clin Cardiol. 2003 Apr;26(4):201-4
Eur J Heart Fail. 2005 Jan;7(1):19-28
Conflict of interest statement
MeSH
- •
- •
- •
- •
Specialties
- •
- •
- •
Copyright
Copyright © 2019 Elsevier Inc. All rights reserved.