Publications

Journal Article Ppublish 11 citations

PubMed: 31669198 DOI: 10.1016/j.hpb.2019.10.008

Asymmetric kinetics of volume and function of the remnant liver after major hepatectomy as a key for postoperative outcome - A case-matched study.

HPB (Oxford) 22(6):855-863

Authors: Stéphanie Truant, Clio Baillet, Maxence Fulbert, Anais Olivier, Géraldine Sergent, Anthony Turpin, Emmanuel Boleslawski, Mehdi El Amrani, Damien Huglo, François-René Pruvot

Affiliations

  • Department of Digestive Surgery and Transplantation, CHU, Univ Nord de France, F-59000 Lille, France.
  • Department of Nuclear Medicine, CHU, Univ Nord de France, F-59000 Lille, France.
  • Department of Digestive Surgery and Transplantation, CHU, Univ Nord de France, F-59000 Lille, France.
  • Department of Radiology, CHU, Univ Nord de France, F-59000 Lille, France.
  • Department of Medical Oncology, CHU, Univ Nord de France, F-59000 Lille, France.

Abstract

BACKGROUND

The kinetics of remnant liver (RL) function is unknown after major hepatectomy (MH), especially in case of post-hepatectomy liver failure (PHLF). This study investigated the change in RL function after MH using 99mTc-labelled-mebrofenin SPECT-scintigraphy and its correlation with RL volume and PHLF.

METHODS

From 2011 to 2015, 125 patients undergoing MH had volumetric assessment by CT and functional SPECT-scintigraphy preoperatively and at day 7 (POD7) and 1 month (1M). RL volume and function changes were compared in (i) overall population and (ii) 17 patients with vs. 42 without PHLF (ISGLS) matched on preoperative RL function.

RESULTS

Increase in RL function correlated poorly with volume increase at POD7 (r = 0.035, p = 0.43) and 1M (r = 0.394, p < 0.0001). Overall, function increase on POD7 (+38.8%) was lower than volume (+49.4%), but comparable at 1M (+78.8% vs. +73%). PHLF patients showed lower function increase on POD7 (+2.1% [-89%-77.8%] vs. +50% [-39%-218%]; p = 0.006). At 1M, 4 PHLF patients died with no function increase despite significant volumetric gain.

CONCLUSIONS

We first showed via sequential SPECT-scintigraphy that RL function increase after MH is slower than volume increase. A poor kinetic of function was correlated with PHLF as early as POD7, contrasting with substantial volume gain in PHLF patients.