View on Pubmed.gov 32746032 | View on doi.org 10.1109/TBME.20...
The Impact of Torso Signal Processing on Noninvasive Electrocardiographic Imaging Reconstructions.
Abstract
GOAL
To evaluate state-of-the-art signal processing methods for epicardial potential-based noninvasive electrocardiographic imaging reconstructions of single-site pacing data.
METHODS
Experimental data were obtained from two torso-tank setups in which Langendorff-perfused hearts (n = 4) were suspended and potentials recorded simultaneously from torso and epicardial surfaces. 49 different signal processing methods were applied to torso potentials, grouped as i) high-frequency noise removal (HFR) methods ii) baseline drift removal (BDR) methods and iii) combined HFR+BDR. The inverse problem was solved and reconstructed electrograms and activation maps compared to those directly recorded.
RESULTS
HFR showed no difference compared to not filtering in terms of absolute differences in reconstructed electrogram amplitudes nor median correlation in QRS waveforms (p > 0.05). However, correlation and mean absolute error of activation times and pacing site localization were improved with all methods except a notch filter. HFR applied post-reconstruction produced no differences compared to pre-reconstruction. BDR and BDR+HFR significantly improved absolute and relative difference, and correlation in electrograms (p < 0.05). While BDR+HFR combined improved activation time and pacing site detection, BDR alone produced significantly lower correlation and higher localization errors (p < 0.05).
CONCLUSION
BDR improves reconstructed electrogram morphologies and amplitudes due to a reduction in lambda value selected for the inverse problem. The simplest method (resetting the isoelectric point) is sufficient to see these improvements. HFR does not impact electrogram accuracy, but does impact post-processing to extract features such as activation times. Removal of line noise is insufficient to see these changes. HFR should be applied post-reconstruction to ensure over-filtering does not occur.
References
Ann Biomed Eng. 2000 Jul;28(7):721-41
J Electrocardiol. 2015 Nov-Dec;48(6):966-74
Circ Arrhythm Electrophysiol. 2012 Oct;5(5):1001-9
Sci Transl Med. 2011 Aug 31;3(98):98ra84
Cited by 22 citations (total)
Journal Article
Novel non-invasive ECG imaging method based on the 12-lead ECG for reconstruction of ventricular activation: A proof-of-concept study.
Electronic publication date February 24, 2023
Patricia Zerlang Fruelund [...] Sam Riahi et al.
Aim
Current non-invasive electrocardiographic imaging (ECGi) methods are often based on complex body surface potential mapping, limiting the clinical applicability. The...
Journal Article Review
Electrocardiographic imaging in the atria.
Electronic publication date March 9, 2023
Ismael Hernández-Romero [...] MarÃa S Guillem et al.
The inverse problem of electrocardiography or electrocardiographic imaging (ECGI) is a technique for reconstructing electrical information about cardiac surfaces from...