Reproducibility of global electrical heterogeneity measurements on 12-lead ECG: The Multi-Ethnic Study of Atherosclerosis.
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, United States of America.
- Epidemiological Cardiology Research Center, Division of Public Health Sciences and Department of Medicine, Cardiology Section, Wake Forest School of Medicine, Winston Salem, NC, United States of America.
- Cardiovascular Division, Department of Medicine, Johns Hopkins School of Medicine, Baltimore, MD, United States of America.
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, United States of America; Cardiovascular Division, Department of Medicine, Johns Hopkins School of Medicine, Baltimore, MD, United States of America. Electronic address: tereshch@ohsu.edu.
Abstract
OBJECTIVE
Vectorcardiographic (VCG) global electrical heterogeneity (GEH) metrics showed clinical usefulness. We aimed to assess the reproducibility of GEH metrics.
METHODS
GEH was measured on two 10-s 12‑lead ECGs recorded on the same day in 4316 participants of the Multi-Ethnic Study of Atherosclerosis (age 69.4 ± 9.4 y; 2317(54%) female, 1728 (40%) white, 1138(26%) African-American, 519(12%) Asian-American, 931(22%) Hispanic-American). GEH was measured on a median beat, comprised of the normal sinus (N), atrial fibrillation/flutter (S), and ventricular-paced (VP) beats. Spatial ventricular gradient's (SVG's) scalar was measured as sum absolute QRST integral (SAIQRST) and vector magnitude QT integral (VMQTi).
RESULTS
Two N ECGs with heart rate (HR) bias of -0.64 (95% limits of agreement [LOA] -5.68 to 5.21) showed spatial area QRS-T angle (aQRST) bias of -0.12 (95%LOA -14.8 to 14.5). Two S ECGs with HR bias of 0.20 (95%LOA -15.8 to 16.2) showed aQRST bias of 1.37 (95%LOA -33.2 to 35.9). Two VP ECGs with HR bias of 0.25 (95%LOA -3.0 to 3.5) showed aQRST bias of -1.03 (95%LOA -11.9 to 9.9). After excluding premature atrial or ventricular beat and two additional beats (before and after extrasystole), the number of cardiac beats included in a median beat did not affect the GEH reproducibility. Mean-centered log-transformed values of SAIQRST and VMQTi demonstrated perfect agreement (Bias 0; 95%LOA -0.092 to 0.092).
CONCLUSION
GEH measurements on N, S, and VP median beats are reproducible. SVG's scalar can be measured as either SAIQRST or VMQTi.
SIGNIFICANCE
Satisfactory reproducibility of GEH metrics supports their implementation.
References
Cardiovasc Digit Health J. 2020 Sep-Oct;1(2):80-88
Biomed Signal Process Control. 2021 Feb;64:102305
Heart Rhythm. 2015 Dec;12(12):2402-10
Ann Noninvasive Electrocardiol. 2019 May;24(3):e12614
Cited by 13 citations (total)
Journal Article
The Importance of Frontal QRS-T Angle in Predicting the Effectiveness and Success of Thrombolytic Therapy in Patients With Acute Pulmonary Embolism.
Electronic publication date February 7, 2023
Mehmet Durgun [...] Mehmet Zülkif Karahan et al.
OBJECTIVE
The frontal QRS-T angle (fQRS-T) is associated with myocardial ischemia and ventricular arrhythmias. On the other hand, acute pulmonary embolism...
Journal Article
Demographic and Methodological Heterogeneity in Electrocardiogram Signals From Guinea Pigs.
Electronic publication date June 21, 2022
Kazi T Haq [...] Nikki Gillum Posnack et al.
Electrocardiograms (ECG) are universally used to measure the electrical activity of the heart; however, variations in recording techniques and/or subject...