Validation of Noninvasive Epicardial and Endocardial Repolarization Mapping.
- Department of Experimental and Clinical Cardiology, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, Netherlands.
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, Location Academic Medical Center, Amsterdam, Netherlands.
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Medical Centre, Nijmegen, Netherlands.
- IHU Liryc, Electrophysiology and Heart Modeling Institute, Fondation Bordeaux Université, Pessac-Bordeaux, France.
Abstract
The detection and localization of electrophysiological substrates currently involve invasive cardiac mapping. Electrocardiographic imaging (ECGI) using the equivalent dipole layer (EDL) method allows the noninvasive estimation of endocardial and epicardial activation and repolarization times (AT and RT), but the RT validation is limited to studies. We aimed to assess the temporal and spatial accuracy of the EDL method in reconstructing the RTs from the surface ECG under physiological circumstances and situations with artificially induced increased repolarization heterogeneity. In four Langendorff-perfused pig hearts, we simultaneously recorded unipolar electrograms from plunge needles and pseudo-ECGs from a volume-conducting container equipped with 61 electrodes. The RTs were computed from the ECGs during atrial and ventricular pacing and compared with those measured from the local unipolar electrograms. Regional RT prolongation (cooling) or shortening (pinacidil) was achieved by selective perfusion of the left anterior descending artery (LAD) region. The differences between the computed and measured RTs were 19.0 ± 17.8 and 18.6 ± 13.7 ms for atrial and ventricular paced beats, respectively. The region of artificially delayed or shortened repolarization was correctly identified, with minimum/maximum RT roughly in the center of the region in three hearts. In one heart, the reconstructed region was shifted by ~2.5 cm. The total absolute difference between the measured and calculated RTs for all analyzed patterns in selectively perfused hearts ( = 5) was 39.6 ± 27.1 ms. The noninvasive ECG repolarization imaging using the EDL method of atrial and ventricular paced beats allows adequate quantitative reconstruction of regions of altered repolarization.
References
Circ Arrhythm Electrophysiol. 2016 May;9(5):
Circulation. 2001 Sep 11;104(11):1306-12
Heart Rhythm. 2021 Feb;18(2):278-287
Circulation. 1987 Feb;75(2):379-86
Cited by 5 citations (total)
Journal Article Review Historical Article
Monitoring and modulating cardiac bioelectricity: from Einthoven to end-user.
Electronic publication date January 9, 2025
Tim De Coster [...] Daniël A Pijnappels et al.
In 2024, we celebrate the 100th anniversary of Willem Einthoven receiving the Nobel Prize for his discovery of the mechanism...
Journal Article
Unlocking cardiac motion: assessing software and machine learning for single-cell and cardioid kinematic insights.
Electronic publication date January 22, 2024
Margherita Burattini [...] Michele Miragoli et al.
The heart coordinates its functional parameters for optimal beat-to-beat mechanical activity. Reliable detection and quantification of these parameters still represent...
Conflict of interest statement
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
MeSH
- •
Specialties
Copyright
Copyright © 2021 van der Waal, Meijborg, Belterman, Streekstra, Oostendorp and Coronel.