View on Pubmed.gov 35448472 | View on doi.org 10.3390/metabo1...
Tumor Size Measurements for Predicting Hodgkin's and Non-Hodgkin's Lymphoma Response to Treatment.
- Department of Biomedical Engineering, University of West Attica, 12243 Athens, Greece.
- Division of Nuclear Medicine, Biomedical Research Foundation of the Academy of Athens, 11527 Athens, Greece.
- 2nd Department of Radiology, Nuclear Medicine Section, Attikon University Hospital of Athens, 12462 Chaidari, Greece.
- Nuclear Medicine Department, General University Hospital of Larissa, 41110 Larissa, Greece.
Abstract
The purpose of this study was to investigate the value of tumor size measurements as prognostic indicators of treatment outcome of Hodgkin's and Non-Hodgkin's lymphomas. F-FDG PET/CT exams before and after treatment were analyzed and metabolic and anatomic parameters-tumor maximum diameter, tumor maximum area, tumor volume, and maximum standardized uptake value (SUVmax)-were determined manually by an expert and automatically by a computer algorithm on PET and CT images. Results showed that the computer algorithm measurements did not correlate well with the expert's standard maximum tumor diameter measurements but yielded better three dimensional metrics that could have clinical value. SUVmax was the strongest prognostic indicator of the clinical outcome after treatment, followed by the automated metabolic tumor volume measurements and the expert's metabolic maximum diameter measurements. Anatomic tumor measurements had poor prognostic value. Metabolic volume measurements, although promising, did not significantly surpass current standard of practice, but automated measurements offered a significant advantage in terms of time and effort and minimized biases and variances in the PET measurements. Overall, considering the limited value of tumor size in predicting response to treatment, a paradigm shift seems necessary in order to identify robust prognostic markers in PET/CT; radiomics, namely combinations of anatomy, metabolism, and imaging, may be an option.
References
Transfusion. 2016 Jul;56(7):1680-3
J Nucl Med. 2009 May;50 Suppl 1:1S-10S
Int J Radiat Oncol Biol Phys. 2002 Jun 1;53(2):353-9
J Clin Oncol. 2010 Mar 10;28(8):1322-8
Cited by 3 citations (total)
Journal Article Comparative Study Validation Study
The predictive power of 18F-FDG PET/CT two-lesions radiomics and conventional models in classical Hodgkin's Lymphoma: a comparative retrospectively-validated study.
Electronic publication date February 27, 2025
Elizabeth Katherine Anna Triumbari [...] Salvatore Annunziata et al.
In a previous preliminary study, radiomic features from the largest and the hottest lesion in baseline 18F-FDG PET/CT (bPET/CT)...
Journal Article
Correlation of PET/CT Maximal Standardized Uptake Values with Clinicopathologic Parameters of Aggressive Non-Hodgkin's Lymphoma.
Electronic publication date May 28, 2025
Yingci Li [...] Mohan Tian et al.
Objective
To investigate the correlation between the maximum standardized uptake value (SUV max) of positron emission tomography (PET)/computed tomography (CT) scanning...
Conflict of interest statement
MeSH
- •
- •
- •
- •
- •
- •
- •
Specialties
- •
- •
- •
- •