View on Pubmed.gov 36679363 | View on doi.org 10.3390/s230205...
ESPRESS.0: Eustachian Tube-Inspired Tactile Sensor Exploiting Pneumatics for Range Extension and SenSitivity Tuning.
- Department of Mechanical Engineering, University of Bristol, Bristol BS8 1TR, UK.
Abstract
Optimising the sensitivity of a tactile sensor to a specific range of stimuli magnitude usually compromises the sensor's widespread usage. This paper presents a novel soft tactile sensor capable of dynamically tuning its stiffness for enhanced sensitivity across a range of applied forces, taking inspiration from the Eustachian tube in the mammalian ear. The sensor exploits an adjustable pneumatic back pressure to control the effective stiffness of its 20 mm diameter elastomer interface. An internally translocated fluid is coupled to the membrane and optically tracked to measure physical interactions at the interface. The sensor can be actuated by pneumatic pressure to dynamically adjust its stiffness. It is demonstrated to detect forces as small as 0.012 N, and to be sensitive to a difference of 0.006 N in the force range of 35 to 40 N. The sensor is demonstrated to be capable of detecting tactile cues on the surface of objects in the sub-millimetre scale. It is able to adapt its compliance to increase its ability for distinguishing between stimuli with similar stiffnesses (0.181 N/mm difference) over a large range (0.1 to 1.1 N/mm) from only a 0.6 mm deep palpation. The sensor is intended to interact comfortably with skin, and the feasibility of its use in palpating tissue in search of hard inclusions is demonstrated by locating and estimating the size of a synthetic hard node embedded 20 mm deep in a soft silicone sample. The results suggest that the sensor is a good candidate for tactile tasks involving unpredictable or unknown stimuli.
References
Sensors (Basel). 2017 Jul 05;17(7):
Acta Biomater. 2021 Sep 1;131:326-340
IEEE Trans Biomed Eng. 2016 Feb;63(2):278-87
Acta Otolaryngol Suppl. 1994;510:92-5
Cited by 7 citations (total)
Journal Article
Abraded optical fibre-based dynamic range force sensor for tissue palpation.
Electronic publication date November 26, 2024
Abu Bakar Dawood [...] Kaspar Althoefer et al.
Tactile information acquired through palpation plays a crucial role in relation to surface characterisation and tissue differentiation - an essential...
Journal Article
Acceptability of Automated Robotic Clinical Breast Examination: Survey Study.
Electronic publication date April 4, 2023
George P Jenkinson [...] Antonia Tzemanaki et al.
BACKGROUND
In the United Kingdom, women aged 50 to 70 years are invited to undergo mammography. However, 10% of invasive breast...
Conflict of interest statement
MeSH
- •