Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes.
Endocr Connect 12(7)
Authors: Jared G Friedman, Kasey Coyne, Grazia Aleppo, Emily D Szmuilowicz
Affiliations
- Division of Endocrinology, Metabolism and Molecular Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois, United States.
Abstract
Hemoglobin A1c (HbA1c) has long been considered a cornerstone of diabetes mellitus (DM) management, as both an indicator of average glycemia and a predictor of long-term complications among people with DM. However, HbA1c is subject to non-glycemic influences which confound interpretation and as a measure of average glycemia does not provide information regarding glucose trends or about the occurrence of hypoglycemia and/or hyperglycemia episodes. As such, solitary use of HbA1c, without accompanying glucose data, does not confer actionable information that can be harnessed to guide targeted therapy in many patients with DM. While conventional capillary blood glucose monitoring (BGM) sheds light on momentary glucose levels, in practical use the inherent infrequency of measurement precludes elucidation of glycemic trends or reliable detection of hypoglycemia or hyperglycemia episodes. In contrast, continuous glucose monitoring (CGM) data reveal glucose trends and potentially undetected hypo- and hyperglycemia patterns that can occur between discrete BGM measurements. The use of CGM has grown significantly over the past decades as an ever-expanding body of literature demonstrates a multitude of clinical benefits for people with DM. Continually improving CGM accuracy and ease of use have further fueled the widespread adoption of CGM. Furthermore, percent time in range correlates well with HbA1c, is accepted as a validated indicator of glycemia, and is associated with the risk of several DM complications. We explore the benefits and limitations of CGM use, the use of CGM in clinical practice, and the application of CGM to advanced diabetes technologies.
MeSH
Diabetes Mellitus, Research Design, Hyperglycemia, Hypoglycemia, Continuous Glucose Monitoring
Cited by
- Glucose Abnormalities Detected by Continuous Glucose Monitoring in Very Old Adults With and Without Diabetes. Diabetes Care, 2025
- 7. Diabetes Technology: Standards of Care in Diabetes-2025. Diabetes Care, 2024
- Comprehensive Assessment of Neuropathy and Metabolic Parameters in Type 1 Diabetic Patients with or Without Using Continuous Glucose Sensors. Int J Mol Sci, 2025
- The Usefulness of the Glucose Management Indicator in Evaluating the Quality of Glycemic Control in Patients with Type 1 Diabetes Using Continuous Glucose Monitoring Sensors: A Cross-Sectional, Multicenter Study. Biosensors (Basel), 2025
- Lifestyle Interventions for Treatment and Remission of Type 2 Diabetes and Prediabetes in Adults: A Clinical Practice Guideline From the American College of Lifestyle Medicine. Am J Lifestyle Med, 2025
- Future of Time-in-Range Goals in the Era of Advanced Hybrid Closed-Loop Automated Insulin Delivery Systems. Diabetes Technol Ther, 2024