Journal Article Ppublish 20 citations
PubMed: 37874856 DOI: 10.1073/pnas.2300095120
Physical mechanisms of red blood cell splenic filtration.
Proc Natl Acad Sci U S A 120(44):e2300095120
Authors: Alexis Moreau, François Yaya, Huijie Lu, Anagha Surendranath, Anne Charrier, Benoit Dehapiot, Emmanuèle Helfer, Annie Viallat, Zhangli Peng
Affiliations
- Aix Marseille Université, CNRS, Centre Interdisciplinaire de Nanoscience de Marseille, Turing Centre for Living Systems, Marseille 13009, France.
- Richard and Loan Hill Department of Biomedical Engineering, University of Illinois, Chicago, IL 60612.
- Aix Marseille Université, CNRS, Institut de Biologie du Développement de Marseille, Turing Centre for Living Systems, Marseille 13009, France.
Abstract
The splenic interendothelial slits fulfill the essential function of continuously filtering red blood cells (RBCs) from the bloodstream to eliminate abnormal and aged cells. To date, the process by which 8 [Formula: see text]m RBCs pass through 0.3 [Formula: see text]m-wide slits remains enigmatic. Does the slit caliber increase during RBC passage as sometimes suggested? Here, we elucidated the mechanisms that govern the RBC retention or passage dynamics in slits by combining multiscale modeling, live imaging, and microfluidic experiments on an original device with submicron-wide physiologically calibrated slits. We observed that healthy RBCs pass through 0.28 [Formula: see text]m-wide rigid slits at 37 °C. To achieve this feat, they must meet two requirements. Geometrically, their surface area-to-volume ratio must be compatible with a shape in two tether-connected equal spheres. Mechanically, the cells with a low surface area-to-volume ratio (28% of RBCs in a 0.4 [Formula: see text]m-wide slit) must locally unfold their spectrin cytoskeleton inside the slit. In contrast, activation of the mechanosensitive PIEZO1 channel is not required. The RBC transit time through the slits follows a [Formula: see text]1 and [Formula: see text]3 power law with in-slit pressure drop and slip width, respectively. This law is similar to that of a Newtonian fluid in a two-dimensional Poiseuille flow, showing that the dynamics of RBCs is controlled by their cytoplasmic viscosity. Altogether, our results show that filtration through submicron-wide slits is possible without further slit opening. Furthermore, our approach addresses the critical need for in vitro evaluation of splenic clearance of diseased or engineered RBCs for transfusion and drug delivery.
MeSH
Erythrocytes, Blood Cells
Cited by
- Mechanical Stimulation of Red Blood Cells Aging: Focusing on the Microfluidics Application. Micromachines (Basel), 2025
- Transit Time Theory for a Droplet Passing through a Slit in Pressure-Driven Low Reynolds Number Flows. Micromachines (Basel), 2023
- PIEZO channels as multimodal mechanotransducers. Biochem Soc Trans, 2025
- Choice of lipid supplementation for in vitro erythroid cell culture impacts reticulocyte yield and characteristics. bioRxiv, 2025
- Reply to Kaestner et al.: Activation of PIEZO1 is not significant for the passage of red blood cells through biomimetic splenic slits. Proc Natl Acad Sci U S A, 2025
- Splenic filtration of red blood cells: Physics, chemistry, and biology need to go hand in hand. Proc Natl Acad Sci U S A, 2025
- An overview of hereditary spherocytosis and the curative effects of splenectomy. Front Physiol, 2025
- Deformability of Heterogeneous Red Blood Cells in Aging and Related Pathologies. Aging Dis, 2025
- Red blood cell passage through deformable interendothelial slits in the spleen: Insights into splenic filtration and hemodynamics. Comput Biol Med, 2024
- Variable surface antigen expression, virulence, and persistent infection by Plasmodium falciparum malaria parasites. Microbiol Mol Biol Rev, 2025
- Erythroblast enucleation at a glance. J Cell Sci, 2024