Publications

Comparative Study
Journal Article Multicenter Study Randomized Controlled Trial
Ppublish 1 citations
Electronic publication date
September 25, 2025

View on Pubmed.gov 39775618 | View on doi.org 10.1055/a-2510-...

Comparison of adenoma detection rate between three-dimensional and standard colonoscopy: a multicenter randomized controlled trial.

Search for publications in this journal Endoscopy - 57(10):1085-1094

Abstract

Improvement in adenoma detection rates (ADRs) effectively reduces the incidence of colorectal cancer. In a simulation study, three-dimensional (3D) colonoscopy provided more anatomical details than standard two-dimensional (2D) colonoscopy and improved ADR. We compared ADRs between 2D and 3D colonoscopy.In this multicenter randomized controlled trial, participants aged ≥40 years undergoing colonoscopy for screening, surveillance, or symptoms between February 2022 and June 2023 were randomized 1:1 into 2D or 3D groups. The primary outcome was ADR. Secondary outcomes included detection rates for flat adenomas, right-sided adenomas, proximal adenomas, advanced adenomas, and sessile serrated lesions (SSLs).Of 348 participants recruited, data from 158 (2D group) and 160 (3D group) were analyzed. Mucosa inspection time was comparable between the 3D (9.8 [SD 2.6] minutes) and 2D (9.4 [SD 3.1] minutes) groups (P = 0.21). Compared with the 2D group, the 3D group had a significantly higher ADR (53.1% vs. 38.6%; difference 14.5% [95%CI 3.7 to 25.4]; P = 0.009), and higher detection rates for flat adenomas (35.0% vs. 21.5%; difference 13.5% [95%CI 3.7 to 23.3]; P = 0.008), right-sided adenomas (26.3% vs. 15.2%; difference 11.1% [95%CI 2.2 to 19.9]; P = 0.02), proximal adenomas (38.1% vs. 23.4%; difference 14.7% [95%CI 4.7 to 24.7]; P = 0.005), and adenomas sized 5-9 mm (45.0% vs. 31.0%; difference 14.0% [95%CI 3.4 to 24.5]; P = 0.01). There was no difference in detection rates for SSLs or advanced adenomas.3D colonoscopy improved adenoma detection without significantly increasing the mucosa inspection time.

References

No references provided.

Conflict of interest statement

The authors declare that they have no conflict of interest.

MeSH

Specialties

Copyright

The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/).