View on Pubmed.gov 40146669 | View on doi.org 10.1371/journal...
Empirical calibration of a simulation model of opioid use disorder.
- Section of Infectious Diseases, Boston Medical Center, Boston, Massachusetts, United States of America.
- Department of Biostatistics, Boston University School of Public Health, Boston, Massachusetts, United States of America.
- Department of Medicine, Boston University School of Medicine, Boston, Massachusetts, United States of America.
- Department of Biostatistics, Brown University School of Public Health, Providence, Rhode Island, United States of America.
Abstract
BACKGROUND
Simulation models of opioid use disorder (OUD) aim at evaluating the impact of different treatment strategies on population-level outcomes. Researching Effective Strategies to Prevent Opioid Death (RESPOND) is a dynamic population, state-transition model that simulates the Massachusetts OUD population synthesizing data from multiple sources. Structural complexity and scarcity of available data for opioid modeling pose a special challenge to model calibration. We propose an empirical calibration approach applicable to complex simulation models in general.
METHODS
We implement an empirical approach to calibrate RESPOND to multiple targets: annual fatal opioid-related overdoses, detox admissions, and OUD population sizes. The empirical calibration involves Latin hypercube sampling for searching a multidimensional parameter space comprising arrivals, overdose rates, treatment transition rates, and substance use state transition probabilities. The algorithm accepts proposed parameters when the respective model outputs lie within pre-determined target uncertainty ranges. This is an iterative process resulting in a set of parameter values for which the model closely fits all the calibration targets. We validated the model assessing its accuracy to projections important for shared decision-making of OUD outside the training data.
RESULTS
The empirical calibration resulted in a model that fits well both calibration and validation targets. The flexibility of the algorithm allowed us to explore structural and parameter uncertainty, reveal underlying relationships between model parameters and identify areas of model improvement for a more accurate representation of the OUD dynamics.
DISCUSSION
The proposed empirical calibration approach is an efficient tool for approximating parameter distributions of complex models, especially under complete uncertainty. Empirically calibrated parameters can be used as a starting point for a more comprehensive calibration exercise, e.g., to inform priors of a Bayesian calibration. The calibrated RESPOND model can be used to improve shared decision-making for OUD.
References
Addiction. 2015 Jun;110(6):996-1005
MMWR Morb Mortal Wkly Rep. 2018 Jan 04;67(5152):1419-1427
Drug Alcohol Depend. 2014 Jul 1;140:69-77
Am J Prev Med. 2021 Feb;60(2):e95-e105
Conflict of interest statement
The authors have declared that no competing interests exist.
MeSH
- •
- •
- •
Specialties
- •
- •
- •
- •
- •
- •
Copyright
Copyright: © 2025 Madushani et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.