Publications

Journal Article
Observational Study
Epublish
Electronic publication date
June 7, 2025

View on Pubmed.gov 40481087 | View on doi.org 10.1038/s41598-...

Agreement between carotid and LVOT non-invasive cardiac output measurements in ED septic shock patients: a prospective observational study.

Search for publications in this journal Sci Rep - 15(1):19911

Abstract

Sepsis significantly impacts the circulatory system and is associated with high mortality rates, particularly in patients with septic shock who require urgent treatment. Non-invasive cardiac output monitoring is a critical bedside tool for assessing fluid responsiveness. This study aimed to evaluate the agreement between cardiac output measurements obtained from the carotid artery and the left ventricular outflow tract (LVOT) in patients with septic shock in the emergency department (ED). A prospective observational study was conducted on adult patients diagnosed with septic shock and admitted to the ED between October 2023 and October 2024. Cardiac output was calculated using the standard formula (CO = VTI × cross-sectional area × heart rate) for both LVOT and carotid measurements. Agreement between LVOT-derived and carotid-derived cardiac output was assessed using Lin's concordance correlation coefficient, intraclass correlation coefficient, Bland-Altman analysis, and percentage error. Forty patients with septic shock were included in the study. The mean carotid blood flow was 0.855 L/min, while the mean cardiac output measured by LVOT echocardiography was 5.329 L/min. Cardiac output measurements derived from carotid artery VTI and LVOT VTI showed a moderate agreement, as demonstrated by Lin's Concordance Correlation Coefficient of 0.527 (p < 0.001) and an Intraclass Correlation Coefficient (absolute agreement) of 0.695 (p < 0.001). Bland-Altman analysis revealed a bias of - 0.47 (95% CI: -2.11 to 1.17), with a concordance interval ranging from - 10.51 (95% CI: -13.35 to - 7.67) to 9.58 (95% CI: 6.74 to 12.42). Non-invasive cardiac output measurements from the carotid artery exhibited only moderate agreement with those derived from the LVOT, accompanied by wide limits of agreement. This indicates that the two methods should not be utilized interchangeably for clinical decision-making in individual patients. Carotid artery measurements should not be regarded as a direct replacement for LVOT examinations.

References

Singer, M. et al. The third international consensus definitions for Sepsis and septic shock (Sepsis-3). JAMA 315, 801–810 (2016).

Phungoen, P. et al. Clinical factors associated with bloodstream infection at the emergency department. BMC Emerg. Med. 21, 30 (2021).

Bauer, M. et al. Mortality in sepsis and septic shock in europe, North America and Australia between 2009 and 2019- results from a systematic review and meta-analysis. Crit. Care. 24, 239 (2020).

Evans, L. et al. Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021. Intensive Care Med. 47, 1181–1247 (2021).

Conflict of interest statement

Declarations. Competing interests: The authors declare no competing interests. Ethical considerations: This study adhered to the principles of the Helsinki Declaration and the guidelines of Good Clinical Practice. The Human Research Ethics Committee of Khon Kaen University approved the study (HE661063), with institutional ethics committee approval obtained on April 3, 2023. Informed consent was obtained from each participant prior to their inclusion in the study.

MeSH

Specialties

Copyright

© 2025. The Author(s).