View on Pubmed.gov 40673467 | View on doi.org 10.1093/bjsopen...
Use of artificial intelligence in the analysis of digital videos of invasive surgical procedures: scoping review.
- National Institute for Health Research Bristol Biomedical Research Centre (Surgical and Orthopeadic Innovation Theme), University of Bristol & Centre for Surgical Research, Bristol Medical School: Population Health Sciences, University of Bristol, Bristol, UK.
- Nuffield Department of Surgical Sciences, Oxford University Hospitals, Oxford, UK.
- School of Medicine, University of Sunderland, Sunderland, UK.
Abstract
INTRODUCTION
Surgical videos are a valuable data source, offering detailed insights into surgical practice. However, video analysis requires specialist clinical knowledge and takes considerable time. Artificial intelligence (AI) has the potential to improve and streamline the interpretation of intraoperative video data. This systematic scoping review aimed to summarize the use of AI in the analysis of videos of surgical procedures and identify evidence gaps.
METHODS
Systematic searches of Ovid MEDLINE and Embase were performed using search terms 'artificial intelligence', 'video', and 'surgery'. Data extraction included reporting of general study characteristics; the overall objective of AI; descriptions of data sets, AI models, and training; methods of data annotation; and measures of accuracy. Data were summarized descriptively.
RESULTS
In all, 122 studies were included. More than half focused on gastrointestinal procedures (75 studies, 61.5%), predominantly cholecystectomy (47, 38.5%). The most common objectives were surgical phase recognition (40 studies, 32.8%), surgical instrument recognition (28, 23.0%), and enhanced intraoperative visualization (23, 18.9%). Of the studies, 79.5% (97) used a single data set and most (92, 75.4%) used supervised machine learning techniques. There was considerable variation across the studies in terms of the number of videos, centres, and contributing surgeons. Forty-seven studies (38.5%) did not report the number of annotators, and details about their experience were frequently omitted (102, 83.6%). Most studies used multiple outcome measures (67, 54.9%), most commonly overall or best accuracy of the AI model (67, 54.9%).
CONCLUSION
This review found that many studies omitted essential methodological details of AI training, testing, data annotation, and validation processes, creating difficulties when interpreting and replicating these studies. Another key finding was the lack of large data sets from multiple centres and surgeons. Future research should focus on curating large, varied, open-access data sets from multiple centres, patients, and surgeons to facilitate accurate evaluation using real-world data.
References
Surg Endosc. 2023 Jul;37(7):5752-5759
Int J Comput Assist Radiol Surg. 2023 May;18(5):939-944
Int J Comput Assist Radiol Surg. 2019 Apr;14(4):697-707
J Biomed Inform. 2009 Apr;42(2):377-81
Conflict of interest statement
MeSH
- •
- •
- •
Specialties
- •
Copyright
© The Author(s) 2025. Published by Oxford University Press on behalf of BJS Foundation Ltd.