View on Pubmed.gov 41837792 | View on doi.org 10.1093/joneph/...
Volume status in dialysis patients at extreme body habitus: a prospective observational study.
- CÚRAM Research Ireland Centre for Medical Devices, University of Galway, Galway, Ireland.
- Health Research Board Clinical Research Facility Galway, University of Galway, Galway, Ireland.
- Department of Renal Medicine, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom.
- Center for Public Health, Department of Epidemiology, Medical University of Vienna, Vienna, Austria.
- Department of Medicine III, Division for Nephrology and Dialysis, Medical University of Vienna, Vienna, Austria.
- Division of Physiology & Pathophysiology, Otto Loewi Research Center for Vascular Biology, Immunology and Inflammation, Medical University of Graz, Graz, Austria.
Abstract
BACKGROUND
Bioimpedance and absolute blood volume measurement are objective assessments of volume status. However, uncertainties remain in their application at extreme body habitus. We aimed to compare blood volume and bioimpedance-based volume status at extreme body habitus and explore normalisation of blood volume in this context to support incorporation of these tools into fluid management decisions.
METHODS
We defined two common extreme volume-status phenotypes in haemodialysis: obese and bioimpedance-dry (n = 29) and lean and bioimpedance-wet (n = 29). Control subjects were haemodialysis patients who were haemodynamically stable with normal volume status (n = 20). We compared post-dialysis blood volume at clinical "target weight", measured by dialysate dilution, in the obese/dry and lean/wet groups with controls. We explored normalisation of blood volume (n = 98) by body mass, lean tissue mass and an anthropometric-based estimate of blood volume determined by Lemmens' formula.
RESULTS
Post-dialysis blood volume normalized for body mass (specific blood volume) was lower in the obese/dry (57.9 mL/kg; P = 0.02) and higher in the lean/wet group (84.5 mL/kg; P = 0.001) than in controls (68.0 mL/kg). These differences were not present for lean tissue mass-normalised or Lemmens' formula-normalised blood volume. Normalising blood volume to body mass results in differences by sex and body mass, whereas normalising to Lemmens blood volume, which accounts for fat mass variation, does not.
CONCLUSIONS
Setting target weights to achieve fixed reference bioimpedance or blood volume values may not be appropriate at extreme body habitus, reinforcing the need for individualised approaches. Normalising blood volume to body mass may exacerbate established measurement bias observed with bioimpedance.
References
Conflict of interest statement
Conflicts of interest: DS received a lecture honorarium from Fresenius Medical Care France and is co-inventor of US12262978B2 patent. The remaining authors have no conflicts of interest to declare.
MeSH
- •
- •
- •
- •
- •
- •
Specialties
- •
- •
- •
- •
- •
- •
- •
- •
- •
- •
- •
Copyright
© The Author(s) 2026. Published by Oxford University Press on behalf of Societa Italiana Nefrologia/Italian Society of Nephrology; Society ownership.