Publications

Journal Article Comparative Study Ppublish

PubMed: 41919621 DOI: 10.5435/JAAOS-D-25-01325

Radiation Exposure and Safety in Minimally Invasive Foot and Ankle Surgery: A Comparative Analysis Between Minimally Invasive Distal First Metatarsal Transverse Osteotomy and Akin Osteotomy vs. Open Modified Lapidus Procedure.

J Am Acad Orthop Surg 34(21):e3078-e3086

Authors: Preston Harrison, Sarah Hall Kiriluk, Kevin Lee, Moawiah Mustafa, John O'Keefe, Shawn Guirau, Ettore Vulcano, A Holly Johnson, Jonathan R M Kaplan, Oliver N Schipper, J Benjamin Jackson, Tyler A Gonzalez

Affiliations

  • University of South Carolina School of Medicine Columbia, Columbia, SC (Harrison); Walter Reed National Military Medical Center, Bethesda, MD (Kiriluk), Prisma Health Radiology, Lexington, SC (Lee); Prisma Health Orthopedics, Lexington, SC (Mustafa, O'Keefe, Guirau, Jackson, Gonzalez); Columbia University Division of Orthopedics at Mount Sinai Medical Center, Miami Beach, FL (Vulcano); Hospital for Special Surgery, New York, NY (Johnson); Duke University Orthopedics, Durham, NC (Kaplan); Anderson Orthopaedic Clinic, Arlington, VA (Schipper).

Abstract

BACKGROUND

Intraoperative fluoroscopy has become essential in orthopaedic surgery, particularly with the rise of minimally invasive surgery (MIS) techniques. As MIS techniques depend more on intraoperative imaging, MIS techniques may necessitate increased fluoroscopy use compared with open procedures. Despite the advantages of minimally invasive foot and ankle surgery, MIS techniques raise concerns about radiation exposure to both patients and surgical staff. The purpose of this study was to evaluate fluoroscopy time and radiation dose (cumulative air kerma) associated with open versus MIS bunion correction, comparing the open modified Lapidus procedure and the minimally invasive distal first metatarsal transverse osteotomy and akin osteotomy (META). It was hypothesized that the META procedure would be associated with increased radiation dose and fluoroscopy time compared with the open modified Lapidus procedure.

METHODS

A retrospective review was conducted for patients who underwent bunion surgery between January 2021 and June 2025 by two fellowship-trained orthopaedic foot and ankle surgeons at a single academic institution. A total of 294 patients met inclusion criteria. Of these, 258 patients underwent a META procedure and 36 underwent an open modified Lapidus procedure. Fluoroscopy time (minutes) and radiation dose (mGy) were compared between the groups.

RESULTS

A mean fluoroscopy time of 2.13 ± 1.27 (range, 0.06 to 7.05) minutes and a radiation dose of 2.02 ± 1.30 (range, 0.05 to 7.52) mGy were observed in the META cohort. An average fluoroscopy time of 1.63 ± 1.83 (range, 0.08 to 7.70) minutes and a radiation dose of 1.31 ± 1.43 (range, 0.07 to 5.98) mGy were observed in the open modified Lapidus cohort. Fluoroscopy time between the cohorts did not differ markedly ( P = 0.123); however, the META group demonstrated a higher radiation dose than the open modified Lapidus group ( P = 0.007).

CONCLUSION

The META procedure had a markedly higher radiation dose compared with the open modified Lapidus procedure, although both remain substantially below the International Commission on Radiological Protection recommended occupational exposure of less than 20.00 mSv per year. Despite the META procedure generating an average radiation dose of 2.02 mGy per case, surgeons receive only 0.50% of the dose; thus, nearly 1,980 procedures would be required to exceed the 20.00 mSv annual occupational limit. These findings suggest that concerns about radiation exposure should not necessarily deter providers from performing the META technique for bunion correction.

LEVEL OF EVIDENCE

III (Retrospective Comparative Study).

MeSH

Osteotomy, Safety, Ankle, Foot, Fluoroscopy, Orthopedics, Radiation Exposure, Bunion, Surgeons