Journal Article Ahead of print
PubMed: 42173050 DOI: 10.1016/j.msard.2026.107250
Automatic multiple sclerosis lesion segmentation in the spinal cord using 3 T and 7 T MP2RAGE images.
Mult Scler Relat Disord 111:107250
Authors: Nilser Laines-Medina, Samira Mchinda, Benoit Testud, Sarah Demortière, Emanuele Pravatà, Govind Nair, Daniel S Reich, Cristina Granziera, Charidimos Tsagkas, Virginie Callot, Julien Cohen-Adad
Affiliations
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France; APHM, CHU Timone, Pôle d'Imagerie Médicale, CEMEREM, Marseille, France; NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada; Mila - Quebec AI Institute, Montreal, QC, Canada.
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France; APHM, CHU Timone, Pôle d'Imagerie Médicale, CEMEREM, Marseille, France.
- Aix Marseille Univ, CNRS, CRMBM, Marseille, France; APHM, CHU Timone, Pôle d'Imagerie Médicale, CEMEREM, Marseille, France; APHM, Hôpital Universitaire Timone, Department of Neuroradiology, Marseille, France.
- APHM, Hôpital Universitaire Timone, Department of Neurology, Marseille, France.
- Department of Neuroradiology, Neurocenter of Southern Switzerland, Lugano, Switzerland; Department of Neuroscience, Imaging and Clinical Sciences, Università G. d'Annunzio, Chieti, Italy.
- Quantitative MRI Core Facility, National Institute of Neurological Disorders and Stroke, National Institutes of Health (NIH), Bethesda, USA.
- Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke, National Institutes of Health (NIH), Bethesda, MD, USA.
- Neurologic Clinic and Policlinic, Departments of Medicine, Clinical Research and Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland; Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland.
- Translational Neuroradiology Section, National Institute of Neurological Disorders and Stroke, National Institutes of Health (NIH), Bethesda, MD, USA; Neurologic Clinic and Policlinic, Departments of Medicine, Clinical Research and Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland; Translational Imaging in Neurology (ThINk) Basel, Department of Biomedical Engineering, University Hospital Basel and University of Basel, Basel, Switzerland.
- NeuroPoly Lab, Institute of Biomedical Engineering, Polytechnique Montreal, Montreal, QC, Canada; Mila - Quebec AI Institute, Montreal, QC, Canada; Functional Neuroimaging Unit, CRIUGM, Université de Montréal, Montreal, QC, Canada; Centre de Recherche du CHU Sainte-Justine, Université de Montréal, Montreal, QC, Canada.
Abstract
PURPOSE
To develop a deep learning-based fully automated framework for segmenting multiple sclerosis (MS) lesions in the spinal cord (SC) using images derived from MP2RAGE acquisitions.
MATERIALS AND METHODS
This retrospective multicenter study included 472 MRI volumes from 422 subjects (mean age 52±12.5 years), comprising 402 patients with MS and 20 healthy controls, acquired at three centers using 3 T and 7 T MRI systems. MP2RAGE-UNI images were preprocessed and analyzed using the Spinal Cord Toolbox (SCT). The multicenter 3 T dataset was divided into training (60%), validation (20%), and testing (20%) subsets, while the 7 T dataset was reserved for testing. The proposed method (UNIseg), based on the nnU-Net v2 architecture, was trained on the multicenter dataset and compared with the current benchmark (seg_ms_lesion_mp2rage, available in SCT v6.3 and earlier versions), which was trained on single-center MP2RAGE-UNI data. Segmentation performance was evaluated using Dice coefficient and lesion-wise metrics by comparing both UNIseg and the benchmark against reference standard. Statistical comparisons were performed using the Wilcoxon signed-rank test.
RESULTS
On the 3 T dataset, UNIseg achieved a mean Dice score of 0.67, significantly outperforming the benchmark (p ≤ 0.01). Lesion-wise sensitivity and precision were 0.81 and 0.92, respectively, with fewer false-positive segmentations. On the 7 T dataset, UNIseg also demonstrated significantly higher performance (p ≤ 0.001), although segmentation performance was lower than that observed at 3 T CONCLUSION: UNIseg provides a robust and efficient approach for segmentation of lesions, improving accuracy compared with existing methods, especially for 3 T data. The trained model and code are publicly available in SCT v6.4 and later.
MeSH
Research Design, Sclerosis, Multiple Sclerosis, Spinal Cord, Wounds And Injuries, Spine