Publications

Journal Article
Randomized Controlled Trial Multicenter Study Comment
Ppublish 8 citations
Open access — free full text available
Open access
Electronic publication date
November 17, 2026

View on Pubmed.gov 42663169 | View on doi.org 10.1001/jama.20... | View the free full text Full text

Cardiovascular Magnetic Resonance to Guide Defibrillator Implantation for LVEF of 36% to 50%: The CMR GUIDE Randomized Clinical Trial.

Search for publications in this journal JAMA - 336(19):1734-1744

Cardiovascular Magnetic Resonance–Guided Management of Mild to Moderate Left Ventricular Systolic Dysfunction Trial Investigators

Abstract

IMPORTANCE

Current guidelines do not recommend primary prevention implantable cardioverter-defibrillators (ICDs) unless a patient's left ventricular ejection fraction (LVEF) is 35% or less. Many sudden cardiac deaths (SCD) occur when LVEF is 36% to 50%. Myocardial scar (a key arrhythmic substrate) can be assessed by late gadolinium enhancement on cardiovascular magnetic resonance (CMR), but robust evidence is lacking regarding a scar-based approach to ICD insertion.

OBJECTIVE

To determine whether implantation of ICDs reduces SCD or hemodynamically significant ventricular arrhythmia (HSVA) in patients with an LVEF of 36% to 50% and myocardial scar.

DESIGN, SETTING, AND PARTICIPANTS

An open-label randomized clinical trial enrolled adults between 2015 and 2022 who had ischemic or nonischemic cardiomyopathy, an LVEF of 36% to 50%, CMR-defined myocardial scar, and were receiving guideline-directed medical therapy at 18 sites in Australia, Germany, and the UK. Follow-up assessments were completed in 2026.

INTERVENTIONS

A primary prevention ICD (n = 180) vs an implantable loop recorder (ILR) (n = 173).

MAIN OUTCOMES AND MEASURES

The primary composite outcome was SCD or HSVA. Five secondary outcomes were evaluated: SCD, HSVA, heart failure-related hospitalization, cardiovascular mortality, and all-cause mortality.

RESULTS

Of 353 patients randomized (median age, 65 years [IQR, 57-61 years]; 18% female; and 72% had an ischemic etiology), 70% had an LVEF of 40% or greater. The median follow-up was 6.3 years (IQR, 4.8-7.6 years). The primary composite outcome occurred in 14 patients (7.8%) in the ICD group compared with 16 patients (9.2%) in the ILR group (hazard ratio [HR], 0.76 [95% CI, 0.37-1.58]). For the individual components of the primary composite outcome, SCD occurred in 3 patients (1.7%) vs 10 patients (5.8%) in the ILR group (HR, 0.26 [95% CI, 0.07-0.95]) and HSVA occurred in 12 patients (6.7%) vs 6 patients (3.5%), respectively (HR, 1.77 [95% CI, 0.65-4.81]). The rates for all-cause mortality, cardiovascular mortality, and heart failure-related hospitalization were similar between groups. In a prespecified analysis of 6 subgroups, the primary outcome occurred less often in patients younger than 70 years in the ICD group (3.3%) vs patients in the ILR group (10.0%) (HR, 0.28 [95% CI, 0.09-0.89]) but not in those aged 70 years or older (16.9% vs 7.5%, respectively) (HR, 2.33 [95% CI, 0.75-7.26]; P = .01 for interaction).

CONCLUSIONS AND RELEVANCE

Implantation of an ICD did not reduce the composite outcome of SCD or HSVA in patients with an LVEF of 36% to 50% and myocardial scar.

TRIAL REGISTRATION

ClinicalTrials.gov Identifier: NCT01918215.

References

Solomon SD, Zelenkofske S, McMurray JJ, et al. ; Valsartan in Acute Myocardial Infarction Trial (VALIANT) Investigators . Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. N Engl J Med. 2005;352(25):2581-2588. doi: 10.1056/NEJMoa043938

Fox CS, Evans JC, Larson MG, Kannel WB, Levy D. Temporal trends in coronary heart disease mortality and sudden cardiac death from 1950 to 1999: the Framingham Heart Study. Circulation. 2004;110(5):522-527. doi: 10.1161/01.CIR.0000136993.34344.41

Huikuri HV, Castellanos A, Myerburg RJ. Sudden death due to cardiac arrhythmias. N Engl J Med. 2001;345(20):1473-1482. doi: 10.1056/NEJMra000650

Moss AJ, Hall WJ, Cannom DS, et al. ; Multicenter Automatic Defibrillator Implantation Trial Investigators . Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. N Engl J Med. 1996;335(26):1933-1940. doi: 10.1056/NEJM199612263352601

Conflict of interest statement

Conflict of Interest Disclosures: Dr Selvanayagam reported receiving grants from the National Heart Foundation of Australia, the Australian National Health and Medical Research Council, Sanofi, Pfizer, and Attralus and receiving personal fees from Sanofi, AstraZeneca, Bristol Myers Squibb, Pfizer, Novartis, Bayer, Amicus, CSL, and Boehringer Ingelheim for consulting or advisory board participation. Dr Cleland reported receiving grants from CSL-Vifor and Pharmacosmos and receiving personal fees from Bayer, Abbott, CSL-Vifor, and Pharmacosmos. Dr Atherton reported receiving grants from the South Australian Health and Medical Research Institute, receiving personal fees from AstraZeneca, Bayer, Boehringer Ingelheim, Bristol Myers Squibb, CSL Seqirus, Novo Nordisk, Novartis, and Sanofi, receiving sponsorship fees from Merck Sharp and Dome and Vifor Pharma, and receiving payments from Eli Lilly that were paid to his employer. Dr Berry reported being employed by the University of Glasgow and that the university holds consultancy and research agreements for his work with Abbott Vascular, Acist, AskBio, AstraZeneca, Auxilius Pharma, CorFlow, Edwards Lifesciences, Merck, NovoSound, Novartis, and Xylocor and the university receives funding from the British Heart Foundation for research undertaken by him. Dr Tonchev reported receiving nonfinancial support from Abbott and Boston Scientific and receiving personal fees from AstraZeneca Australia. Dr Gianacas reported being employed by the George Institute for Global Health and that his salary was supported by funding from the South Australian Health and Medical Research Institute. Dr Jung reported receiving travel support from Biotronik, Medtronic, Abbott, and Boston Scientific. Dr Prasad reported receiving personal fees from Rocket Pharma. Dr De Pasquale reported receiving personal fees from Biotronic, Medtronic, Roche Diagnostics, Novartis, Vifor, Boehringer Ingelheim, AstraZeneca, Eli Lilly, Bayer, and American Regent, receiving grants from Novartis, and receiving nonfinancial support from AstraZeneca and Medtronic. Dr Brachmann reported receiving grants from Biotronik and Johnson & Johnson. No other disclosures were reported.

MeSH

Specialties