Publications

Journal Article Epublish
Open access — free full text available
Open access
Electronic publication date
September 6, 2026

View on Pubmed.gov 42699225 | View on doi.org 10.1093/ckj/sfa... | View the free full text Full text

Fluid overload modifies ambulatory blood pressure and pulse wave characteristics in hemodialysis patients undergoing targeted fluid management.

Search for publications in this journal Clin Kidney J - 19(9):sfag273

Abstract

BACKGROUND

Ambulatory blood pressure (BP) and pulse wave characteristics (PWCs) are stronger predictors of mortality than conventional pre-/post-dialytic BP in hemodialysis. While BP is recommended to be managed primarily by reducing fluid overload (FO), associations of FO with interdialytic BP/PWCs remain unknown.

METHODS

Bioimpedance-derived FO and interdialytic 44-h BP/PWCs were analyzed at baseline and follow-up of a quality improvement project involving targeted fluid management. Trended cosinor linear mixed-effects models assessed intra-patient associations of post-dialysis FO with interdialytic BP/PWCs.

RESULTS

We analyzed 120 visits (77/43 at baseline/follow-up) from 80 patients (70% male; mean age 68 ± 14 years; median dialysis vintage 38 [18-64] months). Post-dialysis FO decreased in baseline hypervolemic patients from 2.7 ± 1.3 L to 0.9 ± 1.7 L. Every 1 L increase in post-dialysis FO at the patient level was associated with increased peripheral BP (systolic: 4.54 mmHg, P < 0.001; diastolic: 2.55 mmHg, P < 0.001), peripheral resistance (0.03 s*mmHg/mL, P = 0.011), augmentation index (1.38%, P = 0.007), wave amplitudes (forward: 0.56 mmHg, P = 0.025; backward: 0.61 mmHg, P = 0.027), reservoir pressure peak (3.83 mmHg, P < 0.001), and pulse wave velocity (0.12 m/s, P = 0.007). Higher FO was associated with decreased interdialytic slopes of all BPs, peripheral resistance, backward wave amplitude, reservoir peak pressure, and pulse wave velocity. FO interacted with circadian rhythms of stroke volume, peripheral resistance, forward wave amplitude, and excess pressure peak.

CONCLUSIONS

We showed that FO in hemodialysis is associated with increased interdialytic BP and PWCs on a patient level, and that FO blunts interdialytic BP/PWC trends. We further establish that physiological BP/PWC patterns may be associated with euvolemic fluid status, hence making the case for tailoring target weight using bioimpedance spectroscopy.

References

Port  FK, Hulbert-Shearon  TE, Wolfe  RA  et al.  Predialysis blood pressure and mortality risk in a national sample of maintenance hemodialysis patients. Am J Kidney Dis. 1999;33:507–17. 10.1016/S0272-6386(99)70188-5.

Robinson  BM, Tong  L, Zhang  J  et al.  Blood pressure levels and mortality risk among hemodialysis patients in the Dialysis Outcomes and Practice Patterns Study. Kidney Int. 2012;82:570–80. 10.1038/ki.2012.136.

Bansal  N, McCulloch  CE, Rahman  M  et al.  Blood pressure and risk of all-cause mortality in advanced chronic kidney disease and hemodialysis: the chronic renal insufficiency cohort study. Hypertension. 2015;65:93–100. 10.1161/HYPERTENSIONAHA.114.04334.

Agarwal  R, Peixoto  AJ, Santos  SFF  et al.  Pre- and postdialysis blood pressures are imprecise estimates of interdialytic ambulatory blood pressure. Clin J Am Soc Nephrol. 2006;1:389–98. 10.2215/CJN.01891105.

Conflict of interest statement

S.W. and C.C.M. are the inventors (not holders) of a patent that is partly used in the ARCSolver algorithm in the Mobil-O-Graph 24 h PWA Monitor. The remaining authors have nothing to declare.

MeSH

Specialties

Copyright

© The Author(s) 2026. Published by Oxford University Press on behalf of the ERA.