Publications

Journal Article
Comparative Study
Ppublish
Open access — free full text available
Open access
Electronic publication date
November 12, 2026

View on Pubmed.gov 42836990 | View on doi.org 10.1007/s00464-... | View the free full text Full text

Access without excess: a comparison of wound infections with disposable versus hybrid trocars in minimally invasive inguinal hernia repairs.

Search for publications in this journal Surg Endosc - 40(11):9272-9279

  • Kimberly P Woo

    Search for this expert
    1
  • Ali Alipouriani

    Search for this expert
    1
  • Abby Gross

    Search for this expert
    1
  • William C Bennett

    Search for this expert
    1
  • Jenny H Chang

    Search for this expert
    1
  • Alvaro Carvalho

    Search for this expert
    1
  • Daphne Remulla

    Search for this expert
    1
  • Kayleigh Risser

    Search for this expert
    1 2
  • Nikhila Yerabandi

    Search for this expert
    1 2
  • Li-Ching Huang

    Search for this expert
    3
  • Alberto Arezzo

    Search for this expert
    4
  • Vittoria Bellato

    Search for this expert
    5
  • Myrthe M Eussen

    Search for this expert
    6
  • Maggie Hodges

    Search for this expert
    7
  • Sheetal Nijhawan

    Search for this expert
    8
  • Marina Yiasemidou

    Search for this expert
    9
  • Kimberly S Miles

    Search for this expert
    1
  • Patricia Sylla

    Search for this expert
    10
  • Shaneeta M Johnson

    Search for this expert
    11 12
  • Lucas R Beffa

    Search for this expert
    1
  • Clayton C Petro

    Search for this expert
    1
  • Ajita S Prabhu

    Search for this expert
    1
  • David M Krpata

    Search for this expert
    1
  • Michael J Rosen

    Search for this expert
    1 13
  • Benjamin T Miller

    Search for this expert
    Contact the corresponding author.
    Reported by OpenAlex: verify on the publication before relying on it.
    14 15

SAGES, EAES Sustainability in Surgery Committee

Abstract

INTRODUCTION

Operating rooms generate 70% of hospital waste. Transitioning from disposable to reusable devices could mitigate surgical waste. Partially reusable, or hybrid, trocars can be used for minimally invasive surgery (MIS), but perceptions of increased infection risk may drive preferences toward disposable trocars. However, no data substantiates this risk. Our analysis of a national hernia outcomes database investigates this presumed association.

METHODS

Using the abdominal core health quality collaborative (ACHQC), we identified high-volume inguinal hernia surgeons who used only disposable trocars for laparoscopic inguinal hernia repair (IHR) and hybrid trocars for robotic IHR. These two surgical approaches served as surrogates to evaluate differences between disposable and hybrid trocars. We performed a query of the ACHQC to identify patients who underwent elective MIS IHR with mesh between 2017 and 2023 by one of the previously identified surgeons.

RESULTS

A total of 34,638 patients met inclusion criteria. After propensity score matching, there were 1191 patients in each group. There was no difference in rates of surgical site infection (SSI), surgical site occurrence requiring procedural intervention (SSOPI), readmission or reoperation between the two groups. There was a statistically significant higher rate of surgical site occurrence (SSO) in the disposable trocar group (5% vs. 2%, p = 0.003). This was driven by a significantly higher rate of hematomas (12% vs 38%, p = 0.007).

CONCLUSION

This study did not find an increased risk of SSI associated with hybrid trocars compared to disposable trocars for MIS inguinal hernia repairs. To decrease surgical waste, surgeons should consider the use of hybrid trocars for laparoscopic surgery.

References

Miller BT, Prabhu AS, Petro CC, Beffa LRA, Carbonell AM, Hope W et al (2023) Laparoscopic versus robotic inguinal hernia repair: 1- and 2-year outcomes from the RIVAL trial. Surg Endosc 37(1):723–728

Luijendijk RW, Hop WC, van den Tol MP, de Lange DC, Braaksma MM, IJzermans JN et al (2000) A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med 343(6):392–398

Yeow M, Wijerathne S, Lomanto D (2022) Intraperitoneal versus extraperitoneal mesh in minimally invasive ventral hernia repair: a systematic review and meta-analysis. Hernia 26(2):533–541

Hayden A, Worth S, Kothari B, Keller W, McGill E, Blackhurst D et al (2023) Outcomes of subsequent abdominal operations after an initial ventral hernia repair. Am J Surg 226(6):896–900

Conflict of interest statement

Declarations. Disclosures: Drs. Kimberly P. Woo, Ali Alipouriani, Abby Gross, William C. Bennett, Jenny H. Chang, Alvaro Carvalho, Daphne Remulla, Li-Ching Huang, Alberto Arezzo, Vittoria Bellato, Myrthe M. M. Eussen, Maggie Hodges, Sheetal Nijhawan, Marina Yiasemidou, Patricia Sylla, Shaneeta M. Johnson, Lucas R. Beffa, Clayton C. Petro, Ajita S. Prabhu, David M. Krpata, Michael J. Rosen, and Benjamin T. Miller have no conflicts of interest or financial ties to disclose. Kayleigh Risser, Nikhila Yerabandi, and Kimberly S. Miles have no conflicts of interest or financial ties to disclose. Ethical approval: This study was approved by the Institutional Review Board (IRB).