Abstract
BACKGROUND
Unexplained changes from a study's analysis plan may increase the risk of bias in study results and undermine confidence in the findings. Discrepancies in methods between protocols and reports have not been examined in interrupted time series (ITS) studies.
METHODS
We searched for peer-reviewed protocols of ITS studies in 22 databases, and results reports addressing each protocol's primary research question. We compared 20 design and analysis items between protocols and their reports, classifying an item as 'discrepant' when the report provided different details about the item compared to the protocol. We judged a discrepancy as 'potentially important' if it could have potentially impacted the results or the study conclusion. We recorded if authors provided justifications for discrepancies.
RESULTS
From 4,590 abstracts, after excluding ongoing studies, we identified 120 eligible ITS protocols, from which 44 protocols (37%) had at least one corresponding results report. Information about handling the complexities of time-series data were frequently missing from the protocol or report, or both, for example, methods of adjusting for autocorrelation (77% of studies, 34/44) and seasonality (82%, 36/44). Potentially important discrepancies were common for eligibility criteria (43%, 19/44), overall length of time series (39%, 17/44), length of each time segment (45%, 20/44), effect measures used to quantify the impact of the interruption (25%, 11/44) and ITS analysis methods used to estimate the model parameters (23%, 10/44). Among studies with important discrepancies, justifications were missing in 50%-100% of cases.
CONCLUSION
Study designs and analysis methods were often not, or insufficiently, reported in ITS studies. Changes to original analysis plans were also prevalent and often unjustified, precluding readers from judging the legitimacy of the changes. Protocols for ITS studies should provide detailed information about the design and analysis methods. Deviations from planned methods should be transparently reported with clear justifications.
References
Lopez Bernal J, Soumerai S, Gasparrini A. A methodological framework for model selection in interrupted time series studies. J Clin Epidemiol. 2018;103:82–91. doi.org .
Ewusie JE, Soobiah C, Blondal E, Beyene J, Thabane L, Hamid JS, Methods. Applications and Challenges in the Analysis of Interrupted Time Series Data: A Scoping Review. J multidisciplinary Healthc. 2020;13:411–23. doi.org .
Hategeka C, Ruton H, Karamouzian M, Lynd LD, Law MR. Use of interrupted time series methods in the evaluation of health system quality improvement interventions: a methodological systematic review. BMJ global health. 2020;5:e003567. doi.org .
Hudson J, Fielding S, Ramsay CR. Methodology and reporting characteristics of studies using interrupted time series design in healthcare. BMC Med Res Methodol. 2019;19:137. doi.org .
Conflict of interest statement
Declarations. Ethics approval and consent to participate: Not applicable. This study was conducted using publicly available data and did not involve human participants, identifiable personal data, animal subjects, or interventions requiring ethical approval. Data related to the included studies was deidentified and anonymised using unique identification numbers. Consent for publication: Not applicable. Competing interests: The authors declare no competing interests.