View on Pubmed.gov 42999535 | View on doi.org 10.1016/j.jhlto... | View the free full text Full text
Preliminary experience with controlled hypothermic storage of donor heart in combined heart transplantation.
- Adult Cardiac Surgery and Transplantation, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint Joseph, Le Plessis Robinson, France.
- Adult Cardiac Surgery and Transplantation, Hôpital Européen Georges-Pompidou, Paris, France.
- Department of Adult Cardiac Disease, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint Joseph, Le Plessis Robinson, France.
- Hepatobiliary Centre, Paul-Brousse Hospital, AP-HP, Paris-Saclay University, INSERM U1193, Villejuif, France.
- Nephrology-Dialysis-Transplantation, Bicêtre Hospital, AP-HP, LeKremlin-Bicêtre, France; INSERM U1184, Le Kremlin-Bicêtre, France.
- Adult Intensive Care Unit, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint Joseph, Le Plessis Robinson, France.
- Congenital Cardiac Surgery and Transplantation, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint Joseph, Le Plessis Robinson, France.
- Adult Cardiac Surgery and Transplantation, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint Joseph, Le Plessis Robinson, France. Department of Adult Cardiac Disease, Marie Lannelongue Hospital, Groupe Hospitalier Paris Saint Joseph, Le Plessis Robinson, France. Inserm UMR_S1358, Medical School, University of Paris Saclay, Le Kremlin Bicêtre, France.
Abstract
While studies have demonstrated improved clinical outcomes with the use of controlled hypothermic storage (CHS) devices in isolated heart transplantation, it has not been evaluated in combined heart transplantation. In this small retrospective study (n=17), we evaluate clinical outcomes after combined heart-liver and heart-kidney transplantation in recipients of donor hearts preserved with conventional ice cold storage (ICS, n=10) versus CHS (n=7). The study found severe early graft dysfunction (EGD) occurred more frequently in the ICS cohort when compared to the CHS cohort (70% vs 0%, respectively). In addition, the CHS cohort had shorter median intensive care unit length of stay (7 days compared to 15.5 days, respectively) as well as fewer post-transplant complications, including sepsis (60% in ICS and 28.6% in CHS), pneumonia (40% in ICS and 14.3% in CHS), stroke (30% in ICS and 0% in CHS), and acute kidney injury requiring dialysis (60% in ICS and 28.6% in CHS). These preliminary findings suggest CHS may improve outcomes in combined heart transplantation.
References
Copeland H., Hayanga J.W.A., Neyrinck A., et al. Donor heart and lung procurement: A consensus statement. J Heart Lung Transplant. 2020;39(6):501–517. doi: 10.1016/j.healun.2020.03.020.
Shudo Y., Leacche M., Copeland H., et al. A paradigm shift in heart preservation: improved post-transplant outcomes in recipients of donor hearts preserved with the SherpaPak System. ASAIO J. 2023;69(11):993–1000. doi: 10.1097/MAT.0000000000002036.
Voigt J.D., Leacche M., Copeland H., et al. Multicenter registry using propensity score analysis to compare a novel transport/preservation system to traditional means on postoperative hospital outcomes and costs for heart transplant patients. ASAIO J. 2023;69(4):345–349. doi: 10.1097/MAT.0000000000001844.
López-Vilella R., González-Costello J., González-VÃlchez F., et al. Combined heart and other organ transplants in Spain: current review of clinical outcomes. COMBI Study. J Heart Lung Transplant. 2026;45(5):756–767. doi: 10.1016/j.healun.2026.01.018.
Conflict of interest statement
The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.