View on Pubmed.gov 6982732 | View on doi.org 10.1016/S0006-3...
Transverse impedance of single frog skeletal muscle fibers.
Abstract
The transverse electrical impedance of single frog skeletal muscle fibers was measured at 31 frequencies that ranged from 1 to 100,000 Hz. Each fiber was bathed entirely in Ringer's solution, but it was positioned so that a central length of 5 mm was in a hollow plastic disk and was electrically isolated from the ends of the fiber. The diameter of the segment of the fiber in the disk was measured and then the segment was pressed from opposite sides by two insulating wedges. Electrical current was passed transversely through the segment between two platinum-platinum black electrodes that were located in the pools of Ringer's solution within the disk. The results were corrected for stray parallel capacitance, series resistance of the Ringer's solution between the fiber and the electrodes, parallel shunt resistance around the fiber, and the phase shift of the measuring apparatus. A nonlinear least-squares routine was used to fit a lumped equivalent circuit to the data from six fibers. The equivalent circuit that was chosen for the fibers contained three parallel branches; each branch was composed of a resistor and a capacitor in series. The model also included a seventh adjustable parameter that was designed to account for the degree of compression of the fibers by the insulating wedges. The branches of the equivalent circuit were assumed to represent the electrical properties of: (a) the myoplasm in series with the membrane capacitance that was exposed directly to the pools of Ringer's solution; (b) the capacitance and series resistance of the transverse tubules that were exposed directly to the pools of Ringer's solution; (c) the membrane capacitance in series with the shunt resistance between the fibers and the insulating wedges. The results gave no indication that current entered the sarcoplasmic reticulum.
References
J Cell Biol. 1965 Jun;25(3):Suppl:209-31
J Gen Physiol. 1967 Nov;50(10):2437-58
J Physiol. 1969 May;201(3):515-33
J Gen Physiol. 1970 Nov;56(5):640-71
Cited by 10 citations (total)
Journal Article Review Research Support, N.I.H., Extramural
Electrical Impedance Myography and Its Applications in Neuromuscular Disorders.
Electronic publication date September 26, 2017
Benjamin Sanchez [...] Seward B Rutkove et al.
Electrical impedance myography (EIM) refers to the specific application of electrical bioimpedance techniques for the assessment of neuromuscular disorders. In...
Journal Article
Electrical conductivity of skeletal muscle tissue: experimental results from different muscles in vivo.
Electronic publication date November 1, 1984
F L Gielen [...] K L Boon et al.
Conflict of interest statement
MeSH
- •