In vivo accuracy testing and clinical experience with the ISG Viewing Wand.
- Department of Neurosurgery, Johns Hopkins Medical Institutions, Baltimore, Maryland, USA.
Abstract
OBJECTIVE
A frameless stereotactic system (the Viewing Wand; Elekta Instruments, Atlanta, GA) has been developed for use with preoperative computed tomography, magnetic resonance imaging, and positron emission tomography as an adjunct for surgical planning and intraoperative navigation. This clinical study was designed to evaluate the safety, efficacy, and accuracy of the Viewing Wand in a variety of intracranial procedures.
METHODS
We used this system in 250 patients undergoing a wide range of neurosurgical procedures from July 1990 to July 1994, to assess its clinical usefulness and safety. In a subset of 45 neurosurgical patients studied between March 1993 and March 1994, a battery of objective accuracy measurements was obtained before and during surgery.
RESULTS
In this series, there were no instances of adverse outcomes attributable to the use of this system. A comparison of two alternative patient-image registration techniques established that the fiducial-fit method was slightly more accurate than the surface-fit method (geometric means = 2.51 and 3.03 mm, respectively). The clinical accuracy achieved with magnetic resonance imaging was nearly equivalent to that with computed tomography.
CONCLUSIONS
On the basis of this clinical series, recommendations are made regarding preoperative scanning parameters, registration techniques, and methods for reestablishing registration if needed during the course of surgery. The primary clinical benefits of the wand in this series were improved intraoperative navigation and surgical safety. For most cases, the wand was also useful in planning the location and size of the scalp incision, craniotomy, or corticotomy, as well as the extent of surgical resection.
References
Cited by 179 citations (total)
Journal Article Research Support, Non-U.S. Gov't
Real-time cardiac catheter navigation on three-dimensional CT images.
Electronic publication date August 16, 2003
Stephen B Solomon [...] Hugh Calkins et al.
INTRODUCTION
Targets for ablation of atrial fibrillation, atrial flutter, and non-idiopathic ventricular tachycardia are increasingly being selected based on anatomic considerations....
Journal Article
Utility of frameless stereotaxy in the resection of skull base and Basal cerebral lesions in children.
Electronic publication date December 16, 2006
E Alshail [...] S Holowka et al.
Since 1991, we have performed nearly 300 stereotactic procedures using the ISG viewing wand on a variety of cranial lesions...