View on Pubmed.gov 9723632 | View on doi.org 10.1016/s0002-9...
Predictors of fluoroscopy time and estimated radiation exposure during radiofrequency catheter ablation procedures.
- Department of Medicine, Johns Hopkins Hospital, Baltimore, Maryland, USA.
Abstract
The objective of this study was to identify factors that predict fluoroscopy duration and radiation exposure during catheter ablation procedures. The patient population included 859 patients who participated in the Atakr Ablation System clinical trial at 1 of 9 centers (398 male and 461 female patients, aged 36 +/- 21 years). Each patient underwent catheter ablation of an accessory pathway, the atrioventricular junction, or atrioventricular nodal reentrant tachycardia using standard techniques. The duration of fluoroscopy was 53 +/- 50 minutes. Factors identified as independent predictors of fluoroscopy duration included patient age and sex, the success or failure of the ablation procedure, and the institution at which the ablation was performed. Catheter ablation in adults required longer fluoroscopy exposure than it did in children. Men required longer durations of fluoroscopy exposure than did women. The mean estimated "entrance" radiation dose was 1.3 +/- 1.3 Sv. The dose needed to cause radiation skin injury was exceeded during 22% of procedures. The overall mean effective absorbed dose from catheter ablation procedures was 0.025 Sv for female patients and 0.017 Sv for male patients. This degree of radiation exposure would result in an estimated 1,400 excess fatal malignancies in female patients and 2,600 excess fatal malignancies in male patients per 1 million patients.
References
Cited by 134 citations (total)
Journal Article Research Support, Non-U.S. Gov't
Real-time cardiac catheter navigation on three-dimensional CT images.
Electronic publication date August 16, 2003
Stephen B Solomon [...] Hugh Calkins et al.
INTRODUCTION
Targets for ablation of atrial fibrillation, atrial flutter, and non-idiopathic ventricular tachycardia are increasingly being selected based on anatomic considerations....
Comparative Study Journal Article
Non-fluoroscopic navigation systems for radiofrequency catheter ablation for supraventricular tachycardia reduce ionising radiation exposure.
Electronic publication date August 5, 2017
Jason See [...] Chi-Keong Ching et al.
INTRODUCTION
The use of non-fluoroscopic systems (NFS) to guide radiofrequency catheter ablation (RFCA) for the treatment of supraventricular tachycardia (SVT) is...
Conflict of interest statement
MeSH
- •
- •
- •
- •
Specialties
- •
- •
- •
- •
- •
- •