View on Pubmed.gov 15899332 | View on doi.org 10.1016/j.ejrad...
The value of high-field MRI (3T) in the assessment of sellar lesions.
- Department of Diagnostic Radiology, Medical University Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.
Abstract
The aim of this study was the evaluation of the normal sellar anatomy in vitro and in vivo with high-field MRI and its application in the diagnosis of sellar pathologies in comparison to standard MRI. All high-field MR images were obtained using a 3T Bruker Medspec 30/80 Scanner with a head birdcage transmit/receive coil and an actively shielded gradient system with a maximum gradient strength of 45 mT/m. Firstly an in vitro study of the sella turcica was performed to depict normal pituitary and sellar anatomy at high field. After a pilot-study this sequence-protocol was established: A RARE sequence (TR/TE = 7790/19 ms; matrix size, 512 x 512; RARE factor = 8, FOV, 200 mm) was used for T2-weighted coronal, axial and sagittal images. A 3D gradient echo sequence with magnetization-preparation (MP-RAGE, TR/TE/TI = 33.5/7.6/800 ms, matrix size, 512 x 512; FOV, 200 mm, effective slice thickness, 1.88 mm; 3 averages) was used for acquisition of T1-weighted pre- and post-contrast images. Between January 2002 and March 200458 patients were enrolled in this study. Seven patients were examined for suspected microadenoma and in 51 patients 3T MRI was used to obtain additional information about the sellar lesion already known to be present from standard MRI. In 21 cases the accuracy of the imaging findings was assessed afterwards by comparison with intraoperative findings. The infiltration of the medial cavernous sinus wall was suspected on standard MRI on 15 sides (47%), on high-field MRI on 9 sides (28%) and could be verified by intraoperative findings on 6 sides (19%). Accordingly, sensitivity to infiltration was 83% for 3T and 67% for standard MRI. Specificity was 84% for 3T and 58% for standard MRI. Moreover, high-field MRI revealed microadenomas in 7 patients with a median diameter of 4mm (range 2-9 mm). The segments of the cranial nerves were seen as mean 4 hypointense spots (range 2-5 spots) on high-field MRI in contrast to 3 spots (range 0-4 spots) on standard MRI. This difference was considerably significant (P < 0.001, Wilcoxon rank sum test). The histopathological results revealed pituitary adenoma in 16 patients and non-adenomatous sellar pathologies such as Rathke's cleft cyst, sarcoidosis, meningeoma and metastasis in 5 patients. High-field MRI is superior to standard MRI for the prediction of invasion of adjacent structures in patients with pituitary adenomas and improves surgical planning of sellar lesion.
References
Cited by 87 citations (total)
Journal Article Research Support, N.I.H., Extramural
An RF dosimeter for independent SAR measurement in MRI scanners.
Electronic publication date August 7, 2014
Di Qian [...] William A Edelstein et al.
PURPOSE
The monitoring and management of radio frequency (RF) exposure is critical for ensuring magnetic resonance imaging (MRI) safety. Commercial MRI...
Journal Article
Hypofractionated stereotactic radiotherapy with CyberKnife for nonfunctioning pituitary adenoma: high local control with low toxicity.
Electronic publication date December 13, 2011
Hiromitsu Iwata [...] Yuta Shibamoto et al.
The aim was to evaluate the clinical outcome of hypofractionated stereotactic radiotherapy (SRT) with CyberKnife for nonfunctioning pituitary adenoma. From...
Conflict of interest statement
MeSH
- •
- •
- •
- •
Specialties
- •
- •
Substances
- •
- •