A technique for double resonant operation of birdcage imaging coils.

Search for publications in this journal IEEE Trans Med Imaging - 8(3):286-94

  • P M Joseph

    Search for this expert
    1
  • D Lu

    Search for this expert

Abstract

The type of radio-frequency (RF) coil known as a high-pass birdcage consists of a set of N; wires arranged axially on the surface of a cylinder and connected by capacitors at each end. Such coils are widely used for NMR imaging because of the high degree of field homogeneity they provide. It is shown how to create homogeneous fields at two frequencies, using an unequal distribution of capacitance. A theoretical analysis which uses the discrete Fourier transform of the currents with respect to the angular positions of the N; wires is presented. A perturbation theory analysis indicates a small sacrifice in homogeneity. The root-mean-square deviation of field magnitude around a circle is proposed as a measure of field inhomogeneity. For the case of double resonance at proton and fluorine frequencies, the loss of homogeneity is at worst 1% and is small compared to the natural inhomogeneity for an N=8 wire coil for radii up to one half the coil radius. The presence of a conducting shield degrades the homogeneity. The theoretical ideas were confirmed in a computer simulation of one particular coil design. A working coil was constructed and images obtained of proton and fluorine phantoms.

References

No references provided.

Cited by 73 citations (total)

Journal Article

Resonant Mode Reduction in Radiofrequency Volume Coils for Ultrahigh Field Magnetic Resonance Imaging.

Electronic publication date November 15, 2011

Search for publications in this journal Materials (Basel)

Yong Pang [...] Xiaoliang Zhang et al.

In a multimodal volume coil, only one mode can generate homogeneous Radiofrequency (RF) field for Magnetic Resonance Imaging. The existence...

Evaluation Study Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't

Design and test of a double-nuclear RF coil for (1)H MRI and (13)C MRSI at 7T.

Electronic publication date January 18, 2018

Search for publications in this journal J Magn Reson

Omar Rutledge [...] Xiaoliang Zhang et al.

RF coil operation at the ultrahigh field of 7T is fraught with technical challenges that limit the advancement of novel...