Publications

Journal Article Ppublish 19 citations
Electronic publication date
August 1, 1977

View on Pubmed.gov 267664 | View on doi.org 10.1017/s002217...

Bacterial contamination in a modern operating suite. 1. Effect of ventilation on airborne bacteria and transfer of airborne particles.

Search for publications in this journal J Hyg (Lond) - 79(1):121-32

Abstract

The effect of ventilation on airborne contamination was studied in a new operating suite containing operating rooms with conventional ventilation (17-20 turnovers/h) and operating rooms with zonal ventilation, where the turnover in the central part of the room was approximately 80/h. The efficacy of the ventilation was first examined with gas tracer experiments and found satisfactory. Experiments using potassium iodide particles showed the transfer between adjacent rooms in the suite to be less than 10(-3)% with closed doors and from 1% to 2.5 x 10(-2)% when the doors were opened once a minute. The transfer between two adjacent operating rooms was calculated to be approximately 10(-4)%. There is thus little risk of spread of airborne infection between operating rooms.Experiments with potassium iodide particles showed that in operating rooms with zonal ventilation the particle concentration in the centre of the room was about one-tenth that in the periphery; in conventionally ventilated operating rooms the concentration was about one-half. With bacteria-carrying particles generated by human activity the concentration in the centre of operating rooms with zonal ventilation was about half that in the periphery both during experimental activity and operations; in conventionally ventilated operating rooms it was about equal in both cases. Bacterial counts at the periphery were found to be lower in rooms with zonal ventilation ( approximately 50 c.f.u./m(3)) than in conventionally ventilated ( approximately 70 c.f.u./m(3)).

References

J Hyg (Lond). 1975 Aug;75(1):31-44

Lancet. 1970 May 9;1(7654):989-93

Clin Orthop Relat Res. 1972 Sep;87:167-87

J Hyg (Lond). 1960 Sep;58:297-305

Cited by 19 citations (total)

Journal Article

Bacterial contamination in a modern operating suite. 3. Importance of floor contamination as a source of airborne bacteria.

Electronic publication date April 1, 1978

Search for publications in this journal J Hyg (Lond)

A Hambraeus [...] G Laurell et al.

The redispersal factor for bacteria-carrying particles from a contaminated floor was determined after mopping, blowing and walking activity. Walking gave...

Journal Article

Wound infections after surgery in a modern operating suite: clinical, bacteriological and epidemiological findings.

Electronic publication date August 1, 1979

Search for publications in this journal J Hyg (Lond)

S Bengtsson [...] G Laurell et al.

A prospective study of 2983 operations in general and orthopaedic surgery during 3 years performed in four operating theatres in...

Conflict of interest statement

No conflict of interest statement provided.

MeSH

Substances