Bacterial contamination in a modern operating suite. 3. Importance of floor contamination as a source of airborne bacteria.

Search for publications in this journal J Hyg (Lond) - 80(2):169-74

Abstract

The redispersal factor for bacteria-carrying particles from a contaminated floor was determined after mopping, blowing and walking activity. Walking gave the highest redispersal factor, 3.5 X 10(-3) m-1, which was three times higher than for blowing and 17 times higher than for mopping. The mean die-away rate for the bacteria-carrying particles used was 1.9/h without ventilation and 14.3/h with ventilation. It was calculated that in the operating rooms less than 15% of the bacteria found in the air were redispersed floor bacteria.

References

J Hyg (Lond). 1977 Aug;79(1):121-32

J Hyg (Lond). 1973 Dec;71(4):787-97

Cited by 78 citations (total)

Journal Article

[Septic OR? Comments on Professor Daschner's statements].

Electronic publication date December 1, 1990

Search for publications in this journal Unfallchirurgie

M Hansis [...] S Weller et al.

Journal Article Research Support, Non-U.S. Gov't

Effectiveness Evaluation of a UV-C-Photoinactivator against Selected ESKAPE-E Pathogens.

Electronic publication date December 27, 2022

Search for publications in this journal Int J Environ Res Public Health

Karyne Rangel [...] Salvatore G De-Simone et al.

Healthcare-associated infections (HAI) worldwide includes infections by ESKAPE-E pathogens. Environmental surfaces and fomites are important components in HAI transmission dynamics,...

Conflict of interest statement

No conflict of interest statement provided.