View on Pubmed.gov 32868420 | View on doi.org 10.1073/pnas.20...
Direct kinetic fingerprinting and digital counting of single protein molecules.
- Single Molecule Analysis Group, Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055.
- Life Science Group, Antibodies Division, Bio-Rad AbD Serotec GmbH, 82178 Puchheim, Germany.
- Department of Internal Medicine, Division of Hematology/Oncology, University of Michigan, Ann Arbor, MI 48109-1055.
- Department of Pediatrics, Division of Hematology/Oncology, University of Michigan, Ann Arbor, MI 48109-1055.
- Life Science Group, Bio-Rad Laboratories, Inc., Hercules, CA 94547.
- Life Science Group, Bio-Rad Laboratories, Inc., Hercules, CA 94547 ning_liu@bio-rad.com nwalter@umich.edu alebuck@umich.edu.
- Single Molecule Analysis Group, Department of Chemistry, University of Michigan, Ann Arbor, MI 48109-1055; ning_liu@bio-rad.com nwalter@umich.edu alebuck@umich.edu.
Abstract
The sensitive and accurate quantification of protein biomarkers plays important roles in clinical diagnostics and biomedical research. Sandwich ELISA and its variants accomplish the capture and detection of a target protein via two antibodies that tightly bind at least two distinct epitopes of the same antigen and have been the gold standard for sensitive protein quantitation for decades. However, existing antibody-based assays cannot distinguish between signal arising from specific binding to the protein of interest and nonspecific binding to assay surfaces or matrix components, resulting in significant background signal even in the absence of the analyte. As a result, they generally do not achieve single-molecule sensitivity, and they require two high-affinity antibodies as well as stringent washing to maximize sensitivity and reproducibility. Here, we show that surface capture with a high-affinity antibody combined with kinetic fingerprinting using a dynamically binding, low-affinity fluorescent antibody fragment differentiates between specific and nonspecific binding at the single-molecule level, permitting the direct, digital counting of single protein molecules with femtomolar-to-attomolar limits of detection (LODs). We apply this approach to four exemplary antigens spiked into serum, demonstrating LODs 55- to 383-fold lower than commercially available ELISA. As a real-world application, we establish that endogenous interleukin-6 (IL-6) can be quantified in 2-µL serum samples from chimeric antigen receptor T cell (CAR-T cell) therapy patients without washing away excess serum or detection probes, as is required in ELISA-based approaches. This kinetic fingerprinting thus exhibits great potential for the ultrasensitive, rapid, and streamlined detection of many clinically relevant proteins.
References
Sci Rep. 2017 Mar 06;7:43824
Nat Biotechnol. 2015 Jul;33(7):730-2
Anal Chem. 2019 Jan 15;91(2):1424-1431
J Am Chem Soc. 2018 Sep 19;140(37):11755-11762
Cited by 51 citations (total)
Journal Article Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't
Direct kinetic fingerprinting and digital counting of single protein molecules.
Electronic publication date October 28, 2020
Tanmay Chatterjee [...] Alexander Johnson-Buck et al.
The sensitive and accurate quantification of protein biomarkers plays important roles in clinical diagnostics and biomedical research. Sandwich ELISA and...
Journal Article
Calibration-free counting of low molecular copy numbers in single DNA-PAINT localization clusters.
Electronic publication date November 26, 2022
Johannes Stein [...] Petra Schwille et al.
Single-molecule localization microscopy (SMLM) has revolutionized light microscopy by enabling optical resolution down to a few nanometer. Yet, localization precision...
Conflict of interest statement
Competing interest statement: The University of Michigan and Bio-Rad Laboratories, Inc. have filed patent applications on technologies described herein, on which M.T., W.B.S, E.P.T., K.J.O., N.L., N.G.W., and A.J.-B. are listed as inventors. M.T., N.G.W., and A.J.-B. are co-founders of aLight Sciences, which sponsored this work and seeks to commercialize the SiMREPS technology. A.K., W.B.S., E.P.T., K.J.O., and N.L. are full-time employees of Bio-Rad Laboratories, Inc., which co-sponsored this work.
MeSH
- •
- •
- •
- •
Specialties
- •
- •
- •
- •
- •
- •
- •
- •
- •
- •
Substances
- •
- •