Comparison Between Ray-Tracing and Full-Wave Simulation for Transcranial Ultrasound Focusing on a Clinical System Using the Transfer Matrix Formalism.
IEEE Trans Ultrason Ferroelectr Freq Control 68(7):2554-2565
Authors: Thomas Bancel, Alexandre Houdouin, Philippe Annic, Itay Rachmilevitch, Yeruham Shapira, Mickael Tanter, Jean-Francois Aubry
Abstract
Only one high-intensity focused ultrasound device has been clinically approved for transcranial brain surgery at the time of writing. The device operates within 650 and 720 kHz and corrects the phase distortions induced by the skull of each patient using a multielement phased array. Phase correction is estimated adaptively using a proprietary algorithm based on computed-tomography (CT) images of the patient's skull. In this article, we assess the performance of the phase correction computed by the clinical device and compare it to: 1) the correction obtained with a previously validated full-wave simulation algorithm using an open-source pseudo-spectral toolbox and 2) a hydrophone-based correction performed invasively to measure the aberrations induced by the skull at 650 kHz. For the full-wave simulation, three different mappings between CT Hounsfield units and the longitudinal speed of sound inside the skull were tested. All methods are compared with the exact same setup due to transfer matrices acquired with the clinical system for N = 5 skulls and T = 2 different targets for each skull. We show that the clinical ray-tracing software and the full-wave simulation restore, respectively, 84% ± 5% and 86% ± 5% of the pressure obtained with hydrophone-based correction for targets located in central brain regions. On the second target (off-center), we also report that the performance of both algorithms degrades when the average incident angles of the acoustic beam at the skull surface increase. When incident angles are higher than 20°, the restored pressure drops below 75% of the pressure restored with hydrophone-based correction.
MeSH
Biomedical Engineering, Brain, Algorithms
Cited by
- Improving Sonication Efficiency in Transcranial MR-Guided Focused Ultrasound Treatment: A Patient-Data Simulation Study. Bioengineering (Basel), 2024
- Treatment envelope of transcranial histotripsy: challenges and strategies to maximize the treatment location profile. Phys Med Biol, 2024
- A comparative study of experimental and simulated ultrasound beam propagation through cranial bones. Phys Med Biol, 2025
- Aberration correction in abdominal histotripsy. Int J Hyperthermia, 2023
- Two-step aberration correction: application to transcranial histotripsy. Phys Med Biol, 2022
- A novel transcranial MR Guided focused ultrasound method based on the ultrashort echo time skull acoustic model and phase retrieval techniques. Sci Rep, 2024
- Treatment Planning and Aberration Correction Algorithm for HIFU Ablation of Renal Tumors. IEEE Trans Ultrason Ferroelectr Freq Control, 2024
- Transcranial ultrasound neuromodulation of the thalamic visual pathway in a large animal model and the dose-response relationship with MR-ARFI. Sci Rep, 2022
- Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound. Adv Drug Deliv Rev, 2022